COPIER (Service mode for copier) > OPTION (Specification setting mode) > NETWORK
NW-WAIT
2
Set connect wait at deep sleep recovery
Detail
To set whether to send wakeup notice after the time set in Settings/Registration menu has elapsed
when recovering from deep sleep.
When 0 is set, wakeup notice is sent after "Waiting Time for Connection at Startup" has elapsed.
When 1 is set, wakeup notice is sent when the machine becomes ready for communication.
Use Case
When a failure of the device management tool occurs
Adj/Set/Operate Method
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
0 to 1
0: Wait, 1: Not wait
Default Value
0
Additional Functions
Mode
Preferences> Network> Waiting Time for Connection at Startup
WLAN-USE
2
Setting of wireless LAN invalidation
Detail
To set whether to disable the wireless LAN.
Bringing in and installation of the wireless LAN equipment may be prohibited depending on user.
In such case, set 0 to prevent the wireless LAN to be used. When 0 is set, [Wireless Connection
Settings] is not displayed in [Settings/Registration].
Use Case
When bringing in and installation of the wireless LAN equipment is prohibited
Adj/Set/Operate Method
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
0 to 1
0: Disabled, 1: Enabled
Default Value
1
Additional Functions
Mode
Preferences> Network> Wireless Connection Settings
WLANPORT
2
Set of port filter at wireless LAN side
Detail
*Operation on this item is restricted by the setting of [Restrict Service Representation Access].
To set whether to open all ports at the wireless LAN side.
When 0 is set, only the specific port is opened (filter is enabled).
Set 1 when using an application which uses a port other than the specific port. All ports are opened
(filter is disabled).
Use Case
Upon user's request
Adj/Set/Operate Method
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
0 to 1
0: Open the specific port, 1: Open all ports
Default Value
0
RAW-PORT
2
[For customization]
LINKWAKE
2
Set of deep sleep recovery at link-up
Detail
To set whether to recover from deep sleep when link-up (disconnection and then connection of
LAN cable) is detected.
Set 0 if the closest hub or switch chatters at link-up. It can prevent recovery from deep sleep
triggered by chattering.
Use Case
When the machine recovers from deep sleep due to chattering of the closest hub or switch
Adj/Set/Operate Method
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
0 to 1
0: Not recovered, 1: Recovered
Default Value
1
WIFIRFCH
2
For R&D
8. Service Mode
748
Summary of Contents for imageRUNNER ADVANCE C255 Series
Page 1: ...Revision 2 0 imageRUNNER ADVANCE C355 C255 Series Service Manual ...
Page 17: ...Product Overview 1 Product Lineup 7 Option 8 Features 11 Specifications 14 Parts Name 18 ...
Page 127: ...Periodical Service 3 Periodically Replacement Parts 117 Consumable parts 118 ...
Page 154: ...4 Remove the Screws 5x 5 Remove the Rear Cover 1 4 Parts Replacement and Cleaning 143 ...
Page 257: ...1 Free the Harness 1 Harness Guide A 1x 1 A 4 Parts Replacement and Cleaning 246 ...
Page 376: ...Error Jam Alarm 7 Overview 366 EError Code 369 Jam Code 457 Alarm Code 464 ...
Page 469: ...Host Machine Cassette PS12 PS11 PS01 PS04 PS05 PS14 PS10 PS101 7 Error Jam Alarm 458 ...
Page 490: ...85 0005 For R D A Operation B Cause C Remedy 7 Error Jam Alarm 479 ...
Page 890: ...4 4x TP M3x6 5 3x 6 2x TP M3x6 7 8 9 Installation 879 ...
Page 891: ...9 1x 10 1x 11 2x 12 4x 13 9 Installation 880 ...
Page 903: ...17 9 Installation 892 ...
Page 914: ...5 6 2x Screw w washer M3x14 7 4x TP M3x6 9 Installation 903 ...
Page 923: ...3 2x 4 Short 1x 5 1x NOTE The removed screw will be used in step 7 6 1x 9 Installation 912 ...
Page 930: ...9 10 11 1x 12 13 9 Installation 919 ...
Page 931: ...14 2x 15 16 2x 17 6x 18 4x 9 Installation 920 ...
Page 932: ... Installing the NFC kit C1 1 1x 2 1x 3 TP M3x4 1x 9 Installation 921 ...