COPIER (Service mode for copier) > OPTION (Specification setting mode) > IMG-FIX
TMP-TBL4
1
Set fixing control temp: heavy paper 4/5
Detail
To set the offset of fixing control temperature for heavy paper 4, 5 (164 to 220 g/m2).
As the value is incremented by 1, the control temperature is increased by 5 deg C from the specified
value.
Increase the value when a fixing failure occurs.
Decrease the value when fixing offset occurs.
Use Case
When offset/fixing failure occurs on heavy paper 4, 5
Adj/Set/Operate Method
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
Caution
Be sure to change the value a little at a time. Otherwise, offset/image failure occurs when setting
an extreme value.
Display/Adj/Set Range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
deg C
Default Value
0
Amount of Change per
Unit
5
TMP-TBL5
1
Fixing control temperature: Thin ppr
Detail
To set the offset of fixing control temperature for thin paper (60 to 63 g/m2).
As the value is incremented by 1, the control temperature changes by 5 deg C from the specified
value.
Increase the value when a fixing failure occurs.
Decrease the value when fixing offset occurs.
Use Case
When offset/fixing failure occurs on thin paper
Adj/Set/Operate Method
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
Caution
Be sure to change the value a little at a time. Otherwise, offset/image failure occurs when setting
an extreme value.
Display/Adj/Set Range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
deg C
Default Value
0
Amount of Change per
Unit
5
TMP-TBL6
1
Fixing control temperature: Envelope
Detail
To set the offset of fixing control temperature for envelope.
As the value is incremented by 1, the control temperature is increased by 5 deg C from the specified
value.
Increase the value when a fixing failure occurs.
Decrease the value when fixing offset occurs.
Use Case
When offset/fixing failure occurs on envelope
Adj/Set/Operate Method
1) Enter the setting value (switch negative/positive by -/+ key) and press OK key.
2) Turn OFF/ON the main power switch.
Caution
Be sure to change the value a little at a time. Otherwise, offset/image failure occurs when setting
an extreme value.
Display/Adj/Set Range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
deg C
Default Value
0
Amount of Change per
Unit
5
8. Service Mode
764
Summary of Contents for imageRUNNER ADVANCE C255 Series
Page 1: ...Revision 2 0 imageRUNNER ADVANCE C355 C255 Series Service Manual ...
Page 17: ...Product Overview 1 Product Lineup 7 Option 8 Features 11 Specifications 14 Parts Name 18 ...
Page 127: ...Periodical Service 3 Periodically Replacement Parts 117 Consumable parts 118 ...
Page 154: ...4 Remove the Screws 5x 5 Remove the Rear Cover 1 4 Parts Replacement and Cleaning 143 ...
Page 257: ...1 Free the Harness 1 Harness Guide A 1x 1 A 4 Parts Replacement and Cleaning 246 ...
Page 376: ...Error Jam Alarm 7 Overview 366 EError Code 369 Jam Code 457 Alarm Code 464 ...
Page 469: ...Host Machine Cassette PS12 PS11 PS01 PS04 PS05 PS14 PS10 PS101 7 Error Jam Alarm 458 ...
Page 490: ...85 0005 For R D A Operation B Cause C Remedy 7 Error Jam Alarm 479 ...
Page 890: ...4 4x TP M3x6 5 3x 6 2x TP M3x6 7 8 9 Installation 879 ...
Page 891: ...9 1x 10 1x 11 2x 12 4x 13 9 Installation 880 ...
Page 903: ...17 9 Installation 892 ...
Page 914: ...5 6 2x Screw w washer M3x14 7 4x TP M3x6 9 Installation 903 ...
Page 923: ...3 2x 4 Short 1x 5 1x NOTE The removed screw will be used in step 7 6 1x 9 Installation 912 ...
Page 930: ...9 10 11 1x 12 13 9 Installation 919 ...
Page 931: ...14 2x 15 16 2x 17 6x 18 4x 9 Installation 920 ...
Page 932: ... Installing the NFC kit C1 1 1x 2 1x 3 TP M3x4 1x 9 Installation 921 ...