E602-2000-00
HDD error
Detection Description
I/O error was detected in the file system after startup.
Remedy
Perform the following in the order while checking whether the error is cleared.
1. Check that the HDD optional board is properly installed.
2. Turn ON the main power, and check whether the error is cleared.
3. Execute the key clear using SST (to make an unformatted disk).
[CAUTION] E602-0001 will be indicated if activating the machine with the unformatted disk.
Therefore, be sure to format the HDD.
4. Enter safe mode using (2+8) startup. Then format the HDD and reinstall the system software
using SST or a USB flash drive.
E602-2001-00
HDD error
Detection Description
Mismatch on encryption operation
Remedy
Perform the following in the order while checking whether the error is cleared.
1. Check that the Main Controller PCB is properly installed.
2. Turn ON the main power, and check whether the error is cleared.
3. Execute the key clear using SST (to make an unformatted disk).
[CAUTION] E602-0001 will be indicated if activating the machine with the unformatted disk.
Therefore, be sure to format the HDD.
4. Enter safe mode using (2+8) startup. Then format the HDD and reinstall the system software
using SST or a USB flash drive.
E602-2002-00
HDD error
Detection Description
Failure of HDD optional board and others
Remedy
Perform the following in the order while checking whether the error is cleared.
1. Turn ON the main power, and check whether the error is cleared.
2. Execute the key clear using SST (to make an unformatted disk).
[CAUTION] E602-0001 will be indicated if activating the machine with the unformatted disk.
Therefore, be sure to format the HDD.
3. Enter safe mode using (2+8) startup. Then format the HDD and reinstall the system software
using SST or a USB flash drive.
4. Replace the Main Controller PCB
E602-5001-00
Encryption Chip error
Detection Description
Error of the encryption chip on the Main Controller
Remedy
[Related parts] Main Controller PCB
[Remedy] Replace the Main Controller PCB
E602-5002-00
HDD error
Detection Description
A non-genuine HDD was detected.
Remedy
1. Replace the HDD with a genuine one.
2. Format the HDD and reinstall the system software using SST or a USB flash drive.
E602-FF01-00
HDD error
Detection Description
An unidentified HDD error was detected at startup.
When this error occurs, the system has not been started normally. Therefore, it may not be
recorded in the error log.
Remedy
[Related parts] R1.00
- Harness between the Main Controller PCB (UN81/J6003, J6004) and the HDD
- HDD
- Main Controller PCB (UN81)
[Remedy] Perform the following in the order while checking whether the error is cleared.
1. Check the related harness/cable and connector.
2. Format the HDD and reinstall the system software using SST or a USB flash drive.
3. Check/replace the related parts.
[Reference] For backup and restoration, refer to "Adjustment> Main Controller System" and
"Appendix> Backup Data List" in the Service Manual.
7. Error/Jam/Alarm
432
Summary of Contents for imageRUNNER ADVANCE C255 Series
Page 1: ...Revision 2 0 imageRUNNER ADVANCE C355 C255 Series Service Manual ...
Page 17: ...Product Overview 1 Product Lineup 7 Option 8 Features 11 Specifications 14 Parts Name 18 ...
Page 127: ...Periodical Service 3 Periodically Replacement Parts 117 Consumable parts 118 ...
Page 154: ...4 Remove the Screws 5x 5 Remove the Rear Cover 1 4 Parts Replacement and Cleaning 143 ...
Page 257: ...1 Free the Harness 1 Harness Guide A 1x 1 A 4 Parts Replacement and Cleaning 246 ...
Page 376: ...Error Jam Alarm 7 Overview 366 EError Code 369 Jam Code 457 Alarm Code 464 ...
Page 469: ...Host Machine Cassette PS12 PS11 PS01 PS04 PS05 PS14 PS10 PS101 7 Error Jam Alarm 458 ...
Page 490: ...85 0005 For R D A Operation B Cause C Remedy 7 Error Jam Alarm 479 ...
Page 890: ...4 4x TP M3x6 5 3x 6 2x TP M3x6 7 8 9 Installation 879 ...
Page 891: ...9 1x 10 1x 11 2x 12 4x 13 9 Installation 880 ...
Page 903: ...17 9 Installation 892 ...
Page 914: ...5 6 2x Screw w washer M3x14 7 4x TP M3x6 9 Installation 903 ...
Page 923: ...3 2x 4 Short 1x 5 1x NOTE The removed screw will be used in step 7 6 1x 9 Installation 912 ...
Page 930: ...9 10 11 1x 12 13 9 Installation 919 ...
Page 931: ...14 2x 15 16 2x 17 6x 18 4x 9 Installation 920 ...
Page 932: ... Installing the NFC kit C1 1 1x 2 1x 3 TP M3x4 1x 9 Installation 921 ...