7
7
7-52
7-52
Error Code > Error Code > Error Code Details
Error Code > Error Code > Error Code Details
Code
Detail
Code
Location
Item
Description
E551 0032 02
Title
a. Error in power fan (F1) of paper folding unit
b. Error in power supply fan of finisher
Description
of detection
a. During driving power fan, fan lock detection signal ON is
detected., or while power fan is stopped, fan lock detection
signal OFF is detected.
b. While fan is stopped, lock is released.
Measures a. Check the connector of the power fan, and replace the fan
if necessary.
b-1. Check the connector of the power supply fan (FAN101),
and replace the fan if necessary.
b-2. Replace the finisher controller PCB.
E551 8001 02
Title
Error in power fan
Description
of detection
Lock signal is detected for 2 sec or more continuously during
the power fan operation.
Measures 1. Check the connector of the power fan, and replace the fan
if necessary.
2. Replace the finisher controller PCB.
E551 8002 02
Title
Error in feed fan
Description
of detection
Lock signal is detected for 2 sec or more continuously during
the feed fan operation.
Measures 1. Check the connector of the feed fan, and replace the fan if
necessary.
2. Replace the finisher controller PCB.
E551 8004 61
Title
Error in the back plate lower cooling fan (front) (FM10) of the
perfect binder.
Description
of detection
The lock signal of the back plate lower cooling fan (front)
(FM10) is detected.
Measures 1. Replace the back plate lower cooling fan (front) (FM10).
2. Replace the slave controller PCB.
E551 8005 61
Title
Error in the back plate lower cooling fan (rear) (FM11) of the
perfect binder.
Description
of detection
The lock signal of the back plate lower cooling fan (rear)
(FM11) is detected.
Measures 1. Replace the back plate lower cooling fan (rear) (FM11).
2. Replace the slave controller PCB.
E551 8006 61
Title
Error in the back plate upper cooling fan of the perfect binder
(front) (FM12).
Description
of detection
The lock signal of the back plate upper cooling fan (front)
(FM12) is detected.
Measures 1. Replace the back plate upper cooling fan (front) (FM12).
2. Replace the slave controller PCB.
Code
Detail
Code
Location
Item
Description
E551 8007 61
Title
Error in the back plate upper cooling fan (rear) (FM13) of the
perfect binder
Description
of detection
The lock signal of the back plate upper cooling fan (rear)
(FM13) is detected.
Measures 1. Replace the back plate upper cooling fan (rear) (FM13).
2. Replace the slave controller PCB.
E551 8008 61
Title
Error in the signature cooling 2 fan (front) (FM6) of the perfect
binder
Description
of detection
The lock signal of the signature cooling 2 fan (front) (FM6) is
detected.
Measures 1. Replace the signature cooling 2 fan (front) (FM6).
2. Replace the slave controller PCB.
E551 8009 61
Title
Error in the signature cooling 2 fan (rear) (FM7) of the perfect
binder
Description
of detection
The lock signal of the signature cooling 2 fan (rear) (FM7) is
detected.
Measures 1. Replace the signature cooling 2 fan (rear) (FM7).
2. Replace the slave controller PCB.
E551 800A 61
Title
Error in the signature cooling 1 fan (front) (FM8) of the perfect
binder
Description
of detection
The lock signal of the signature cooling 1 fan (front) (FM8) is
detected.
Measures 1. Replace the signature cooling 1 fan (front) (FM8).
2. Replace the slave controller PCB.
E551 800B 61
Title
Error in the signature cooling 1 fan (rear) (FM9) of the perfect
binder
Description
of detection
The lock signal of the signature cooling 1 fan (rear) (FM9) is
detected.
Measures 1. Replace the signature cooling 1 fan (rear) (FM9).
2. Replace the slave controller PCB.
E551 800C 61
Title
Error in the glue supply cooling fan (upper) (FM4) of the
perfect binder.
Description
of detection
The lock signal of the glue supply cooling fan (upper) (FM4)
is detected.
Measures 1. Replace the glue supply cooling fan (upper) (FM4).
2. Replace the slave controller PCB.
E551 800D 61
Title
Error in the glue supply cooling fan (lower) (FM5) of the
perfect binder.
Description
of detection
The lock signal of the glue supply cooling fan (lower) (FM5) is
detected.
Measures 1. Replace the glue supply cooling fan (lower) (FM5).
2. Replace the slave controller PCB.
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...