Technology > eM Controller-E1 > Settings procedures
Technology > eM Controller-E1 > Settings procedures
(4) e-Maintenance/ imageWARE Remote settings
e-Maintenance/ imageWARE Remote setting items are follow.
Setting Item
Strings
Description
E-RDS
2 bytes
0: Disable/ 1:Enable e-Maintenance/ imageWARE
Remote system to send device information, counter
data, error statuses to the UGW.
Default value is 0 (not in use)
RGW-ADR
129 bytes
(NULL included,
SJIS not allowed)
The UGW address by default : https://a01.ugwdevice.
net/ugw/agentif010
RGW-PORT
4 bytes
The UGW Port Number by default : 443
Validation: 1~ 65535
COM-TEST
To perform Communication test with UGW and set "OK!"/
"NG!" as the result.
COM-LOG
Detailed communication log displays the last 5 error
information, consisting of data, error code, and error
reasons up to now
Max 30 latest loggings retained
Max 128 characters (not containing NULL) for Error
information
CLEAR
ERDS-DAT
Reset E-RDS settings
a. Select Servicemode > COPIER>Function > Clear>ERDS-DAT, and then press [OK].
* In case of [MODELIST], is selected, a guide will be displayed, if the item which should be
operated is chosen and
button is pressed. In case of [MODELIST CLASSIC],
button is not displayed.
T-2-104
F-2-273
b.
Select Service mode > COPIER > Function > INSTALL > E-RDS, enter [1] and press [OK].
This turns ON the function that enables communication with the UGW.
F-2-274
F-2-275
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...