Technology > eM Controller-E1 > Service cautions
Technology > eM Controller-E1 > Service cautions
Service cautions
After performing the following service actions, it is necessary to perform Service mode
> COPIER > Function > Clear > ERDS-DAT and Service mode > COPIER > Function >
INSTALL > COM-TEST.
Failure to do so will result that the counter transmitting value to the UGW may become
unusual.
• System upgrade
• HDD format and system installation
• COPIER > Function > Clear > MN-CONT
Also, after replacing the main controller board, all settings must be reprogrammed.
The following settings in service mode must not be change unless there are specific
instructions to do so. Changing these values will cause error in communication with UGW.
Service mode > COPIER > Function > INSTALL > RGW-PORT
Default: 443
Service mode > COPIER > Function >INSTALL > RGW-ADR
Default: https://a01.ugwdevice.net/ugw/agentif010