E864 0005 11
Title
Contact failure on connector (J3004) of path motor driver
PCB (PCB5)
Description
of detection
When contact failure on J3004 connector is detected.
Measures 1. Check the connector (J3004).
2. Replace the path motor driver PCB.
3. Replace the POD deck controller PCB.
E864 0005 12
Title
Contact failure on connector (J3004) of path motor driver
PCB (PCB5)
Description
of detection
When contact failure on J3004 connector is detected.
Measures 1. Check the connector (J3004).
2. Replace the path motor driver PCB.
3. Replace the POD deck controller PCB.
E864 0005 13
Title
Contact failure on connector (J3004) of path motor driver
PCB (PCB5)
Description
of detection
When contact failure on J3004 connector is detected.
Measures 1. Check the connector (J3004).
2. Replace the path motor driver PCB.
3. Replace the POD deck controller PCB.
E864 0005 21
Title
Contact failure on connector (J3004) of path motor driver
PCB (PCB5)
Description
of detection
When contact failure on J3004 connector is detected.
Measures 1. Check the connector (J3004).
2. Replace the path motor driver PCB.
3. Replace the POD deck controller PCB.
E864 0006 11
Title
Error in vertical path front cover 24V
Description
of detection
24V power of vertical path motor supplied from the path
motor driver PCB failed.
Measures 1. Replace the Vertical path cover interlock switch.
2. Check the connection of the harness between the vertical
path cover interlock switch and the path motor driver PCB.
3. Replace the path motor driver PCB.
E864 0006 12
Title
Error in vertical path front cover 24V
Description
of detection
24V power of vertical path motor supplied from the path
motor driver PCB failed.
Measures 1. Replace the Vertical path cover interlock switch.
2. Check the connection of the harness between the vertical
path cover interlock switch and the path motor driver PCB.
3. Replace the path motor driver PCB.
Code
Detail
Code
Location
Item
Description
E864 0006 13
Title
Error in vertical path front cover 24V
Description
of detection
24V power of vertical path motor supplied from the path
motor driver PCB failed.
Measures 1. Replace the Vertical path cover interlock switch.
2. Check the connection of the harness between the vertical
path cover interlock switch and the path motor driver PCB.
3. Replace the path motor driver PCB.
E864 0006 21
Title
Error in vertical path front cover 24V
Description
of detection
24V power of vertical path motor supplied from the path
motor driver PCB failed.
Measures 1. Replace the Vertical path cover interlock switch.
2. Check the connection of the harness between the vertical
path cover interlock switch and the path motor driver PCB.
3. Replace the path motor driver PCB.
E864 0007 11
Title
Error in deck horizontal path cover_24V
Description
of detection
24V power of horizontal path motor supplied from the path
motor driver PCB failed.
Measures 1. Replace the deck horizontal path cover interlock switch.
2. Check the connection of the harness between the deck
horizontal path interlock switch and the path motor driver
PCB.
3. Replace the path motor driver PCB.
E864 0007 12
Title
Error in deck horizontal path cover_24V
Description
of detection
24V power of horizontal path motor supplied from the path
motor driver PCB failed.
Measures 1. Replace the deck horizontal path cover interlock switch.
2. Check the connection of the harness between the deck
horizontal path interlock switch and the path motor driver
PCB.
3. Replace the path motor driver PCB.
E864 0007 13
Title
Error in deck horizontal path cover_24V
Description
of detection
24V power of horizontal path motor supplied from the path
motor driver PCB failed.
Measures 1. Replace the deck horizontal path cover interlock switch.
2. Check the connection of the harness between the deck
horizontal path interlock switch and the path motor driver
PCB.
3. Replace the path motor driver PCB.
E864 0007 21
Title
Error in deck horizontal path cover_24V
Description
of detection
24V power of horizontal path motor supplied from the path
motor driver PCB failed.
Measures 1. Replace the deck horizontal path cover interlock switch.
2. Check the connection of the harness between the deck
horizontal path interlock switch and the path motor driver
PCB.
3. Replace the path motor driver PCB.
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...