7
7
7-194
7-194
Error Code > Alarm Code > Alarm Code Details
Error Code > Alarm Code > Alarm Code Details
Location Code
Description
Detailed description
04
- 0558 POD2: Left floatation fan
of lower deck: end of life/
brokerage of fan
Operation: Lower deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0559 POD2: Side right fan of
lower deck does not rotate:
breakdown
Operation: Lower deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0560 POD2: Side left fan of
lower deck does not rotate:
breakdown
Operation: Lower deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0561 POD2: Error is detected
while lower deck suction
fan stops
Operation: Lower deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0562 POD2: Over load is
detected on lower deck.
Operation: Alarm is displayed while normal
operation is kept.
How to release: Open/close the deck to release
04
- 0563 POD2: Setting failure of
trailing edge retainer on
lower deck is detected.
Operation: Alarm is displayed while normal
operation is kept.
How to release: Open/close the deck to release
04
- 0564 POD2: Error is detected
while the lower deck side
fan 1 stops.
Operation: Lower deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0565 POD2: Error is detected
while the lower deck side
fan 2 stops.
Operation: Lower deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0568 POD2: Suction fan of
lower deck does not rotate:
breakdown
Operation: Lower deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0637 POD3: Upper deck lifter
motor does not descend.
Operation: Upper deck is not used/upper deck lifter
motor is stopped.
How to release: Turn OFF/ON to release
04
- 0638 POD3: Lifter lower limit
sensor of upper deck is
broken.
(Lifter does not descend.)
Operation: Upper deck is not used/upper deck lifter
motor is stopped.
How to release: Turn OFF/ON to release
04
- 0639 POD3: Upper deck lifter
motor does not ascend.
Operation: Upper deck is not used/upper deck lifter
motor is stopped.
How to release: Turn OFF/ON to release
04
- 0640 POD3:L ifter lower limit
sensor of upper deck is
broken.
(Lifter does not ascend.)
Operation: Upper deck is not used/upper deck lifter
motor is stopped.
How to release: Turn OFF/ON to release
04
- 0641 POD3: Paper surface
sensor of upper deck is
broken.
Operation: Upper deck is not used/upper deck lifter
motor is stopped.
How to release: Turn OFF/ON to release
04
- 0642 POD3: Lifter upper limit
sensor of upper deck
exceeds the upper limit.
Operation: Alarm is displayed while normal
operation is kept.
How to release: Open/close the deck to release
Location Code
Description
Detailed description
04
- 0643 POD3: Lifter lower limit
sensor of upper deck
exceeds the lower limit.
Operation: Upper deck is not used/lifter is lifted to
the lowest position.
How to release: Turn OFF/ON to release
04
- 0644 POD3: Remain level count
of upper deck exceeds the
upper limit.
Operation: Upper deck is not used/upper deck lifter
motor is stopped.
How to release: Turn OFF/ON to release
04
- 0645 POD3:R emain level count
of upper deck exceeds the
lower limit.
Operation: Upper deck is not used/upper deck lifter
motor is stopped.
How to release: Turn OFF/ON to release
04
- 0646 POD3: Supply position
sensor flag of upper deck is
broken.
Operation: Upper deck is not used/upper deck lifter
motor is stopped.
How to release: Turn OFF/ON to release
04
- 0647 POD3: Connector of supply
position sensor on upper
deck is disconnected.
Operation: Alarm is displayed while normal
operation is kept.
How to release: Open/close the deck to release
04
- 0648 POD3: Connector of right
separation fan on upper
deck is disconnected.
Operation: Upper deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0649 POD3: Right separation fan
of upper deck: end of life/
brokerage of fan
Operation: Upper deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0650 POD3: Connector of left
separation fan on upper
deck is disconnected.
Operation: Upper deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0651 POD3: Left separation fan
of upper deck: end of life/
brokerage of fan
Operation: Upper deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0652 POD3: Connector of right
floatation fan on upper deck
is disconnected.
Operation: Upper deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0653 POD3: Right floatation fan
of upper deck: end of life/
brokerage of fan
Operation: Upper deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0654 POD3: Connector of middle
floatation fan on upper deck
is disconnected.
Operation: Upper deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0655 POD3: Middle floatation fan
of upper deck: end of life/
brokerage of fan
Operation: Upper deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0656 POD3: Auto adjustment of
floatation fan is failed on
upper deck.
Operation: Alarm is displayed while normal
operation is kept.
How to release: Turn OFF/ON and readjusted.
04
- 0657 POD3: Connector of left
floatation fan on upper deck
is disconnected.
Operation: Upper deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...