7
7
7-28
7-28
Error Code > Error Code > Error Code Details
Error Code > Error Code > Error Code Details
Code
Detail
Code
Location
Item
Description
E315 0520 00
Title
Error in device timeout
Description
of detection
If interruption does not occur within 2 min from start-up.
Measures 1. DDI-S (Check RCON and I/F)
2. Replace the main controller PCB.
E315 0521 00
Title
Error in device abnormal termination
Description
of detection
When an abnormal interruption is detected after startup.
Measures 1. DDI-S (Check RCON and I/F)
2. Replace the main controller PCB.
E315 0530 00
Title
Error in device timeout
Description
of detection
If interruption does not occur within 2 min from start-up.
Measures 1. Turn OFF/ON.
2. If symptom occurs frequently, replace the main controller
PCB.
E315 0531 00
Title
Error in device abnormal termination
Description
of detection
When an abnormal interruption is detected after startup.
Measures 1. Turn OFF/ON.
2. If symptom occurs frequently, replace the main controller
PCB.
E315 0540 00
Title
Error in device timeout
Description
of detection
If interruption does not occur within 2 min from start-up.
Measures 1. Turn OFF/ON.
2. If symptom occurs frequently, replace the main controller
PCB.
E315 0541 00
Title
Error in device abnormal termination
Description
of detection
When an abnormal interruption is detected after startup.
Measures 1. Turn OFF/ON.
2. If symptom occurs frequently, replace the main controller
PCB.
E315 0550 00
Title
Error in device timeout
Description
of detection
If interruption does not occur within 2 min from start-up.
Measures 1. DDI-S (Check RCON and I/F)
2. Replace the main controller PCB.
E315 0551 00
Title
Error in device abnormal termination
Description
of detection
When an abnormal interruption is detected after startup.
Measures 1. DDI-S (Check RCON and I/F)
2. Replace the main controller PCB.
Code
Detail
Code
Location
Item
Description
E315 0560 00
Title
Error in device timeout
Description
of detection
If interruption does not occur within 2 min from start-up.
Measures 1. DDI-S (Check RCON and I/F)
2. Replace the main controller PCB.
E315 0561 00
Title
Error in device abnormal termination
Description
of detection
When an abnormal interruption is detected after startup.
Measures 1. DDI-S (Check RCON and I/F)
2. Replace the main controller PCB.
E350 0000 00
Title
ECO-ID PCB-related error
Description
of detection
Measures Contact a sales company.
E350 0001 00
Title
ECO-ID PCB-related error
Description
of detection
Measures Contact a sales company.
E350 0002 00
Title
ECO-ID PCB-related error
Description
of detection
Measures Contact a sales company.
E350 0003 00
Title
ECO-ID PCB-related error
Description
of detection
Measures Contact a sales company.
E350 3000 00
Title
ECO-ID PCB-related error
Description
of detection
Measures Contact a sales company.
E351 0000 00
Title
ECO-ID PCB-related error
Description
of detection
Measures Contact a sales company.
E354 0001 00
Title
ECO-ID PCB-related error
Description
of detection
Measures Contact a sales company.
E354 0002 00
Title
ECO-ID PCB-related error
Description
of detection
Measures Contact a sales company.
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...