8
8
8-29
8-29
Service Mode > COPIER > DISPLAY (Status Display Mode) > CCD
Service Mode > COPIER > DISPLAY (Status Display Mode) > CCD
COPIER> DISPLAY> CCD
GAIN-ER
Gain level of img sensr even bit(R) frnt
Lv.2 Details
Displaying the Red gain level adjustment value in even-numbered bit
on CMOS sensor of front side scanner unit.
Continuous display of upper limit can determine a failure of the
scanner unit/reader controller PCB.
Use case
• When replacing the reader controller PCB
• When the scanned image is faulty
Adj/set/operate method N/A (display only)
Display/adjust/set range 0 to FFFF
Appropriate target value 16 to 246
LAMP-BW
Scan light intensity adj VL(B&W): front
Lv.2 Details
Displaying the LED light intensity adj value of front side scanner unit
in B&W scanning mode.
Use case
When image failure occurs at front side scanning in B&W mode.
Adj/set/operate method N/A (display only)
Display/adjust/set range 20 to 163
Appropriate target value 20 to 163
Supplement/memo
LED cannot be replaced individually. Replace the scanner unit.
LAMP-CL
Scan light intensity adj VL(color): frnt
Lv.2 Details
Displaying the LED light intensity adj value of front side scanner unit
in color scanning mode.
Use case
When image failure occurs at front sidescanning in color mode.
Adj/set/operate method N/A (display only)
Display/adjust/set range 33 to 163
Appropriate target value 33 to 163
Supplement/memo
LED cannot be replaced individually. Replace the scanner unit.
LAMP2-BW
Scan light intensity adj VL(B&W): back
Lv.2 Details
Displaying the LED light intensity adj value of back side scanner unit
in B&W scanning mode.
Use case
When image failure occurs at back side scanning in B&W mode.
Adj/set/operate method N/A (display only)
Display/adjust/set range 20 to 163
Appropriate target value 20 to 163
Supplement/memo
LED cannot be replaced individually. Replace the scanner unit.
LAMP2-CL
Scan light intensity adj VL(color): back
Lv.2 Details
Displaying the LED light intensity adj value of back side scanner unit
in color scanning mode.
Use case
When image failure occurs at back side scanning in color mode.
Adj/set/operate method N/A (display only)
Display/adjust/set range 33 to 163
Appropriate target value 33 to 163
Supplement/memo
LED cannot be replaced individually. Replace the scanner unit.
COPIER> DISPLAY> CCD
OFST-BW
Img sensor offset value (B&W) [Front]
Lv.2 Details
Displaying the CMOS sensor offset value at B&W scanning.
Use case
When image failure occurs at front side scanning in B&W mode.
Adj/set/operate method N/A (display only)
Display/adjust/set range 1 to 95
Appropriate target value 1 to 95
OFST-CL
Img sensor offset value (color) [Front]
Lv.2 Details
Displaying the CMOS sensor offset value at color scanning.
Use case
When image failure occurs at front side scanning in color mode.
Adj/set/operate method N/A (display only)
Display/adjust/set range 1 to 95
Appropriate target value 1 to 95
OFST2-BW
Img sensor offset value (B&W) [Back]
Lv.2 Details
Displaying the CMOS sensor offset value at B&W scanning.
Use case
When image failure occurs at back side scanning in B&W mode.
Adj/set/operate method N/A (display only)
Display/adjust/set range 1 to 95
Appropriate target value 1 to 95
GAIN-BW1
Img sensor gain level adj VL1(B&W): Frnt
Lv.2 Details
Displaying the CMOS sensor B&W gain level adjustment value 1 of
front side scanner unit.
Use case
When image failure occurs at front side scanning in B&W mode.
Adj/set/operate method N/A (display only)
Display/adjust/set range 1 to 47
Appropriate target value 1 to 47
GAIN-BW2
Img sensor gain level adj VL2(B&W): Frnt
Lv.2 Details
Displaying the CMOS sensor B&W gain level adjustment value 2 of
front side scanner unit.
Use case
When image failure occurs at front side scanning in B&W mode.
Adj/set/operate method N/A (display only)
Display/adjust/set range 1 to 47
Appropriate target value 1 to 47
GAIN-BW3
Img sensor gain level adj VL3(B&W): Frnt
Lv.2 Details
Displaying the CMOS sensor B&W gain level adjustment value 3 of
front side scanner unit.
Use case
When image failure occurs at front side scanning in B&W mode.
Adj/set/operate method N/A (display only)
Display/adjust/set range 1 to 47
Appropriate target value 1 to 47
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...