Error Code > Error Code > Error Code Details
Error Code > Error Code > Error Code Details
Code
Detail
Code
Location
Item
Description
E102 0001 05
Title
Error in scanner EEPROM reading
Description
of detection
When an error is detected on the EEPROM reading of
polygon scanner.
Measures 1. Check the connector.
2. Replace the laser scanner unit.
3. Replace the DC controller PCB.
E110 0010 05
Title
Error in scanner motor (Drive fails to start.)
Description
of detection
When VLOCK signal cannot be detected during the FG
rotation of polygon scanner (either the VLOCK signal cannot
be detected within 7.5 sec from startup or VLOCK signal
cannot be detected for 1 sec continuously after the VLOCK
signal is detected once.).
“x” in the detailed code represents the numeric values.
Occurrence timing can be identified by this numeric values (for
design review). As a field remedy, laser scanner needs to be
replaced regardless of this numeric values.
Measures 1. Check the connector.
2. Replace the laser scanner unit.
3. Replace the DC controller PCB.
E110 0011
05
Title
Error in scanner motor (Revolution fails to reach the specified
value.)
Description
of detection
When VLOCK signal cannot be detected during the FG
rotation of polygon scanner (either the VLOCK signal cannot
be detected within 7.5 sec from startup or VLOCK signal
cannot be detected for 1 sec continuously after the VLOCK
signal is detected once.).
“x” in the detailed code represents the numeric values.
Occurrence timing can be identified by this numeric values (for
design review). As a field remedy, laser scanner needs to be
replaced regardless of this numeric values.
Measures 1. Check the connector.
2. Replace the laser scanner unit.
3. Replace the DC controller PCB.
E110 0012 05
Title
Error in scanner motor (BD detection fails.)
Description
of detection
When VLOCK signal cannot be detected during the FG
rotation of polygon scanner (either the VLOCK signal cannot
be detected within 7.5 sec from startup or VLOCK signal
cannot be detected for 1 sec continuously after the VLOCK
signal is detected once.).
“x” in the detailed code represents the numeric values.
Occurrence timing can be identified by this numeric values (for
design review). As a field remedy, laser scanner needs to be
replaced regardless of this numeric values.
Measures 1. Check the connector.
2. Replace the laser scanner unit.
3. Replace the DC controller PCB.
Code
Detail
Code
Location
Item
Description
E110 0013 05
Title
Error in scanner motor (Detection fails after BD detection.)
Description
of detection
When VLOCK signal cannot be detected during the FG
rotation of polygon scanner (either the VLOCK signal cannot
be detected within 7.5 sec from startup or VLOCK signal
cannot be detected for 1 sec continuously after the VLOCK
signal is detected once.).
“x” in the detailed code represents the numeric values.
Occurrence timing can be identified by this numeric values (for
design review). As a field remedy, laser scanner needs to be
replaced regardless of this numeric values.
Measures 1. Check the connector.
2. Replace the laser scanner unit.
3. Replace the DC controller PCB.
E110 0015 05
Title
Error in scanner motor (Rotation accuracy error during phase
control)
Description
of detection
When VLOCK signal cannot be detected during the FG
rotation of polygon scanner (either the VLOCK signal cannot
be detected within 7.5 sec from startup or VLOCK signal
cannot be detected for 1 sec continuously after the VLOCK
signal is detected once.).
“x” in the detailed code represents the numeric values.
Occurrence timing can be identified by this numeric values (for
design review). As a field remedy, laser scanner needs to be
replaced regardless of this numeric values.
Measures 1. Check the connector.
2. Replace the laser scanner unit.
3. Replace the DC controller PCB.
E110 0016 05
Title
Error in scanner motor (Error after phase lock)
Description
of detection
When VLOCK signal cannot be detected during the FG
rotation of polygon scanner (either the VLOCK signal cannot
be detected within 7.5 sec from startup or VLOCK signal
cannot be detected for 1 sec continuously after the VLOCK
signal is detected once.).
“x” in the detailed code represents the numeric values.
Occurrence timing can be identified by this numeric values (for
design review). As a field remedy, laser scanner needs to be
replaced regardless of this numeric values.
Measures 1. Check the connector.
2. Replace the laser scanner unit.
3. Replace the DC controller PCB.
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...