7
7
7-34
7-34
Error Code > Error Code > Error Code Details
Error Code > Error Code > Error Code Details
Code
Detail
Code
Location
Item
Description
E501 0005 51
Title
Communication error with the stacker
Description
of detection
NACK reception
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
E501 0005 52
Title
Communication error with the 2nd stacker
Description
of detection
NACK reception
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
E501 0006 51
Title
Communication error with the stacker
Description
of detection
Error reception by parallel signal from the option controller
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
E501 0006 52
Title
Communication error with the 2nd stacker
Description
of detection
Error reception due to parallel signal from the option controller
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
E501 0011
51
Title
Communication error with the stacker
Description
of detection
Communication error was notified with parallel signal because
the stacker detects communication error
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
Code
Detail
Code
Location
Item
Description
E501 0011
52
Title
Communication error with the 2nd stacker
Description
of detection
Communication error was notified with parallel signal because
the stacker detects communication error
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
E501 0012 51
Title
Communication error with the stacker
Description
of detection
There was an overrun error, parity error, or flaming error while
receiving 1-byte data
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
E501 0012 52
Title
Communication error with the 2nd stacker
Description
of detection
There was an overrun error, parity error, or flaming error while
receiving 1-byte data
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
E501 0013 51
Title
Communication error with the stacker
Description
of detection
Transmission process is not completed despite 5-time
transmission retry
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
E501 0013 52
Title
Communication error with the 2nd stacker
Description
of detection
Transmission process is not completed despite 5-time
transmission retry
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...