8
8
8-430
8-430
Service Mode > SORTER > ADJUST
Service Mode > SORTER > ADJUST
SORTER> ADJUST
GLU-LOW
Glue level lower limit adj value: trimmr
Lv.1 Details
To enter the fluid level 1 (lower limit) adj value of glue level
thermistor.
Use case
When the master controller PCB/EEPROM is replaced
Display/adj/set range
0 to 255
Default value
0
GLU-UP
Glue level upper limit adj value: trimmr
Lv.1 Details
To enter the fluid level 2 (higher limit) adj value of glue level
thermistor.
Use case
When the master controller PCB/EEPROM is replaced
Display/adj/set range
0 to 255
Default value
0
GLU-EDG1
Top edge treatment (in top-tail): trimmr
Lv.1 Details
To set the edge treatment amount at top (rear) side in top-tail
trimming.
As the value is increased by 1, the edge treatment amount is
increased by 1 mm.
Use case
• To prevent the glue peeling at the edge: decrease the edge
treatment amount
• To prevent the over glue: increase the edge treatment amount
Display/adj/set range
0 to 5
Unit
1 mm
Default value
0
GLU-EDG2
Tail edge treatment (in top-tail): trmmr
Lv.1 Details
To set the edge treatment amount at tail (rear) side in top-tail
trimming.
As the value is increased by 1, the edge treatment amount is
increased by 1 mm.
Use case
• To prevent the glue peeling at the edge: decrease the edge
treatment amount
• To prevent the over glue: increase the edge treatment amount
Display/adj/set range
0 to 5
Unit
1 mm
Default value
2
GLU-EDG3
Top edge treatment (in no trim): trimmer
Lv.1 Details
To set the edge treatment amount at top (rear) side in no top-tail
trimming.
As the value is increased by 1, the edge treatment amount is
increased by 1 mm.
Use case
• To prevent the glue peeling at the edge: decrease the edge
treatment amount
• To prevent the over glue: increase the edge treatment amount
Display/adj/set range
0 to 5
Unit
1 mm
Default value
2
SORTER> ADJUST
GLU-EDG4
Tail edge treatment (in no trim): trimmr
Lv.1 Details
To set the edge treatment amount at tail (front) side in no top-tail
trimming.
As the value is increased by 1, the edge treatment amount is
increased by 1 mm.
Use case
• To prevent the glue peeling at the edge: decrease the edge
treatment amount
• To prevent the over glue: increase the edge treatment amount
Display/adj/set range
0 to 5
Unit
1 mm
Default value
0
GLU-AMT1
Glue amount adj1: trimmer
Lv.1 Details
To adjust the glue application amount on the return way at the glue
thick application by changing the space between the paper stack
(thickness 0 to 1.4 mm) and the scraper plate.
As the value is changed by 1, the space gets wider/narrower by
0.05 mm (as the space is widened, the glue application amount is
increased).
+: space is widened (application amount increased)
-: space is narrowed (application amount is decreased)
Use case
When the glue application amount is not appropriate on the paper
stack
Display/adj/set range
-20 to 20
Unit
0.05 mm
Default value
0
GLU-AMT2
Glue amount adj2: trimmer
Lv.1 Details
To adjust the glue application amount on the return way at the glue
thick application by changing the space between the paper stack
(thickness 1.5 to 3.4 mm) and the scraper plate.
As the value is changed by 1, the space gets wider/narrower by
0.05 mm (as the space is widened, the glue application amount is
increased).
+: space is widened (application amount increased)
-: space is narrowed (application amount is decreased)
Use case
When the glue application amount is not appropriate on the paper
stack
Display/adj/set range
-20 to 20
Unit
0.05 mm
Default value
0
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...