7
7
7-65
7-65
Error Code > Error Code > Error Code Details
Error Code > Error Code > Error Code Details
Code
Detail
Code
Location
Item
Description
E584 8003 02
Title
Error in the stack delivery lower/shutter motor
Description
of detection
The shutter does not come off the shutter close detection
sensor.
Measures 1. Check the connector of the shutter close detection sensor
(S148), and replace the sensor if necessary.
2. Check the connector of the stack delivery lower/shutter
motor (M122), and replace the motor if necessary.
3. Replace the finisher controller PCB.
E584 8004 02
Title
Error in the stack delivery lower/shutter motor
Description
of detection
The shutter close detection sensor does not detect the
shutter.
Measures 1. Check the connector of the shutter close detection sensor
(S148), and replace the sensor if necessary.
2. Check the connector of the stack delivery lower/shutter
motor (M122), and replace the motor if necessary.
3. Replace the finisher controller PCB.
E585 8001 02
Title
Stack retainer motor error
Description
of detection
HP sensor does not turn ON even though 250 msec has
passed since the start of operation.
Measures 1. Check the connector of the stack retainer HP sensor.
2. Check the connector of the stack retainer motor.
3. Replace the stack retainer HP sensor.
4. Replace the stack retainer motor.
5. Replace the finisher controller PCB.
E585 8002 02
Title
Stack retainer motor error
Description
of detection
HP sensor does not turn OFF even though 250 msec has
passed since the start of operation.
Measures 1. Check the connector of the stack retainer HP sensor.
2. Check the connector of the stack retainer motor.
3. Replace the stack retainer HP sensor.
4. Replace the stack retainer motor.
5. Replace the finisher controller PCB.
E586 8001 51
Title
Error in lock of decurler shift motor (M11) of the stacker
Description
of detection
Decurler shift HP sensor (S14) failed to be OFF even though
specified period of time has passed in the case of adjusting
decurler pressure
Measures 1. Check the connector of the decurler shift HP sensor (S14),
and replace the sensor if necessary.
2. Replace the decurler shift motor (M11).
3. Replace the master controller PCB.
Code
Detail
Code
Location
Item
Description
E586 8001 52
Title
Error in lock of decurler shift motor (M11) of the 2nd stacker
Description
of detection
Decurler shift HP sensor (S14) failed to be OFF even though
specified period of time has passed in the case of adjusting
decurler pressure
Measures 1. Check the connector of the decurler shift HP sensor (S14),
and replace the sensor if necessary.
2. Replace the decurler shift motor (M11).
3. Replace the master controller PCB.
E586 8002 51
Title
Error in lock of decurler shift motor (M11) of the stacker
Description
of detection
Decurler shift HP sensor (S14) failed to be ON even though
specified period of time has passed in the case of adjusting
decurler pressure
Measures 1. Replace the decurler shift HP sensor (S14).
2. Replace the decurler shift motor (M11).
3. Replace the master controller PCB.
E586 8002 52
Title
Error in lock of decurler shift motor (M11) of the 2nd stacker
Description
of detection
Decurler shift HP sensor (S14) failed to be ON even though
specified period of time has passed in the case of adjusting
decurler pressure
Measures 1. Replace the decurler shift HP sensor (S14).
2. Replace the decurler shift motor (M11).
3. Replace the master controller PCB.
E586 8011
51
Title
Error in lock of decurler feed motor (M14) of the stacker
Description
of detection
The lock signal was monitored 1.5 sec after the motor has
started to be driven, and locking state continued for specified
period of time.
Measures 1. Replace the decurler feed motor (M14).
2. Replace the master controller PCB.
E586 8011
52
Title
Error in lock of decurler feed motor (M14) of the 2nd stacker
Description
of detection
The lock signal was monitored 1.5 sec after the motor has
started to be driven, and locking state continued for specified
period of time.
Measures 1. Replace the decurler feed motor (M14).
2. Replace the master controller PCB.
E587 0001 51
Title
Error in lock of cooling fan 1 (FAN1) of the stacker
Description
of detection
Lock signal has been ON continuously for specified period of
time
Measures 1. Replace the cooling fan 1 (FAN1).
2. Replace the master controller PCB.
E587 0001 52
Title
Error in lock of cooling fan 1 (FAN1) of the 2nd stacker
Description
of detection
Lock signal has been ON continuously for specified period of
time
Measures 1. Replace the cooling fan 1 (FAN1).
2. Replace the master controller PCB.
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...