Address
bit
Name
Symbol
Remarks
P100
15
Middle deck J2102 connect sensor
-
0: Not connected,
1: Connected
14
Middle deck lifter lower limit switch
MS702
0: Normal, 1: Lower limit
13
Middle deck lifter lower position sensor
PS712
0: Lower position,
1: Others
12
Middle deck supply position sensor
PS709
0: Supply position,
1: Others
11
Middle deck J2150 connect sensor
-
0: Not connected,
1: Connected
10
Middle deck suction fan error
FM701
0: Error, 1: Normal
9
Middle deck pickup driver PCB 24V error
sensor
PCB701 0: Normal, 1: Error
8
Middle deck open/close sensor
PS707
0: Open, 1: Close
7
Middle deck indicator driver PCB 12V
error sensor
PCB704 0: Normal, 1: Error
6
Middle deck driver PCB 5V error sensor
PCB703 0: Normal, 1: Error
5
Middle deck driver PCB 12V error sensor PCB703 0: Normal, 1: Error
4
Middle deck driver PCB 24V error sensor PCB703 0: Normal, 1: Error
3
Middle deck J2101 connect sensor
-
0: Not connect,
1: Connect
2
Middle deck interlock switch
MS703
0: Open, 1: Close
1
Middle deck side right fan
FM707
0: Error, 1: Normal
0
Middle deck side left fan
FM708
0: Error, 1: Normal
P101
15
Power supply cooling fan 1 ON
FM2
0: OFF, 1: ON
14
Path driver cooling fan ON
FM1
0: OFF, 1: ON
13
Double feeding detection PCB power
supply ON
PCB6 /
PCB7
0: OFF, 1: ON
12
Power supply cooling fan 2 ON
FM3
0: OFF, 1: ON
11
-
-
-
10
-
-
-
9
-
-
-
8
-
-
-
7
Lower vertical path motor 2-I1
M13
-
6
Lower vertical path motor 2-I0
M13
-
5
Lower vertical path motor 2-2PHASE
M13
0: 2 phase, 1: 1-2 phase
4
Lower vertical path motor 2-CLK
M13
1: Counted
3
Lower vertical path motor 1-I1
M12
-
2
Lower vertical path motor 1-I0
M12
-
1
Lower vertical path motor 1-2PHASE
M12
0: 2 phase, 1: 1-2 phase
0
Lower vertical path motor 1CLK
M12
1: Counted
Address
bit
Name
Symbol
Remarks
P102
15
Upper vertical path motor 1-I1
M10
-
14
Upper vertical path motor 1-I0
M10
-
13
Upper vertical path motor 1-2PHASE
M10
0: 2 Phase, 1: 1-2 Phase
12
Upper vertical path motor 1-CLK
M10
1: Count
11
Lower vertical path motor 3-I1
M14
-
10
Lower vertical path motor 3-I0
M14
-
9
Lower vertical path motor 3-2PHASE
M14
0: 2 Phase, 1: 1-2 Phase
8
Lower vertical path motor 3-CLK
M14
1: Count
7
Multi path motor-I1
M23
-
6
Multi path motor-I0
M23
-
5
Multi path motor-2PHASE
M23
0: 2 Phase, 1: 1-2 Phase
4
Multi path motor-CLK
M23
1: Count
3
Multi path motor 2-I1
M11
-
2
Upper vertical path motor 2-I0
M11
-
1
Upper vertical path motor 2-2PHASE
M11
0: 2 Phase, 1: 1-2 Phase
0
Upper vertical path motor 2-CLK
M11
1: Count
P103
15
Multi path sensor 2
PS15
0: No paper, 1: Paper
14
Multi path sensor 1
PS14
0: No paper, 1: Paper
13
Upper vertical path sensor 2
PS2
0: No paper, 1: Paper
12
Upper vertical path sensor 1
PS1
0: No paper, 1: Paper
11
-
-
-
10
Lower vertical path sensor 3
PS5
0: No paper, 1: Paper
9
Lower vertical path sensor 2
PS4
0: No paper, 1: Paper
8
Lower vertical path sensor 1
PS3
0: No paper, 1: Paper
7
-
-
-
6
-
-
-
5
-
-
-
4
-
-
-
3
Horizontal path sensor 4
PS9
0: Outside HP, 1: Inside
HP
2
Horizontal path sensor 3
PS8
0: Outside HP, 1: Inside
HP
1
Horizontal path sensor 2
PS7
0: Outside HP, 1: Inside
HP
0
Horizontal path sensor 1
PS6
0: Outside HP, 1: Inside
HP
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...