4
4
4-140
4-140
Parts Replacement and Cleaning > Main Unit > Removing Reversal Unit
Parts Replacement and Cleaning > Main Unit > Removing Reversal Unit
5) Pull out the fixing feed unit.
F-4-239
6) Remove the left lower cover.
• 6 screws
x6
F-4-240
7) Remove the 3 connectors.
F-4-241
8) Pull out the reversal unit in the direction of the arrow.
• 2 screws
• 2 retainers
x2
F-4-242