E001 0051 05
Title
Error in difference of high temperature (software detection)
Description
of detection
Error in high temperature detection of fixing roller. (Detected
temperature of fixing roller sub thermistor exceeds 240 deg C
for 1 sec)
Measures 1. Replace the fixing roller sub thermistor.
2. Replace the fixing roller main thermistor.
3. Replace the fixing heater.
4. Replace the fixing heater control PCB.
E001 0060 05
Title
Error in difference of high temperature (software detection)
Description
of detection
Error in high temperature detection of pressure roller.
(Detected temperature of pressure roller main thermistor
exceeds 210 deg C for 1 sec)
Measures 1. Replace the pressure roller main thermistor.
2. Replace the pressure roller heater.
3. Replace the fixing heater control PCB.
E001 0061 05
Title
Error in difference of high temperature (software detection)
Description
of detection
Error in high temperature detection of pressure roller.
(Detected temperature of pressure roller sub thermistor
exceeds 210 deg C for 1 sec)
Measures 1. Replace the pressure roller sub thermistor.
2. Replace the pressure roller main thermistor.
3. Replace the pressure roller heater.
4. Replace the fixing heater control PCB.
E001 0070 05
Title
Error in difference of high temperature (software detection)
Description
of detection
Error in high temperature detection of external heat upper
roller. (Detected temperature of main thermistor on the
external heat upper roller exceeds 247 deg C for 1 sec)
Measures 1. Clean the external heat upper roller main thermistor.*
2. Replace the external heat roller thermistor.*
3. Replace the external heat heater 1.*
4. Replace the fixing heater control PCB.
*: When the counter value of the external heat upper roller is
less than 1,000,000. Replace the external heat roller unit in
the case of 1,000,000 or more.
E001 0071 05
Title
Error in difference of high temperature (software detection)
Description
of detection
Error in high temperature detection of external heat upper
roller. (Detected temperature of sub thermistor on the external
heat upper roller exceeds 247 deg C for 1 sec)
Measures 1. Clean the external heat upper roller sub thermistor.*
2. Replace the external heat roller thermistor.*
3. Replace the external heat heater 1.*
4. Replace the fixing heater control PCB.
*: When the counter value of the external heat upper roller is
less than 1,000,000. Replace the external heat roller unit in
the case of 1,000,000 or more.
Code
Detail
Code
Location
Item
Description
E001 0080 05
Title
Error in difference of high temperature (software detection)
Description
of detection
Error in high temperature detection of external heat lower
roller. (Detected temperature of main thermistor on the
external heat lower roller exceeds 247 deg C for 1 sec)
Measures 1. Clean the external heat lower roller main thermistor.*
2. Replace the external heat roller thermistor.*
3. Replace the external heat heater 2.*
4. Replace the fixing heater control PCB.
*: When the counter value of the external heat lower roller is
less than 1,000,000. Replace the external heat roller unit in
the case of 1,000,000 or more.
E001 0081 05
Title
Error in difference of high temperature (software detection)
Description
of detection
Error in high temperature detection of external heat lower
roller. (Detected temperature of sub thermistor on the external
heat lower roller exceeds 247 deg C for 1 sec)
Measures 1. Clean the external heat lower roller sub thermistor.*
2. Replace the external heat roller thermistor.*
3. Replace the external heat heater 2.*
4. Replace the fixing heater control PCB.
*: When the counter value of the external heat lower roller is
less than 1,000,000. Replace the external heat roller unit in
the case of 1,000,000 or more.
E001 9999 05
Title
Error in difference of high temperature (hardware detection)
Description
of detection
Before an error is detected as temperature difference error in
high temperature (software detection), the relay was turned
OFF by the hardware detection.
Measures This error does not usually occur because software detection
is performed before hardware detection.
E002 0011
05
Title
Error in difference of center/edge temperature (software
detection)
Description
of detection
Error in difference of fixing roller temperature. (Detected
temperature difference between the main thermistor and the
sub thermistor of fixing roller is 100 deg C or more for 1 sec.)
Measures 1. Replace the fixing roller main thermistor.
2. Replace the fixing roller sub thermistor.
3. Replace the fixing heater.
4. Replace the fixing heater control PCB.
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...