4
4
4-238
4-238
Parts Replacement and Cleaning > Periodic Replacing Parts, Durable Parts, Cleaning Parts > Cleaning Procedure During ITB Replacement
Parts Replacement and Cleaning > Periodic Replacing Parts, Durable Parts, Cleaning Parts > Cleaning Procedure During ITB Replacement
z
4) Open the shutter arm and clean the ITB edge sensor with a blower.
Caution :
If the toner is stuck on
the white plate of the
edge sensor window
or the shutter arm, ITB
displacement control
error may occur.
ITB edge sensor
Shutter arm
Blower
F-4-504
5) Turn the ITB drive motor and dry-wipe it with the lint-free paper in vertical direction.
ITB drive motor
ITB drive roller
F-4-505
6) Put a paper between the fixing feed unit and the ITB frame
Paper
F-4-506