7
7
7-17
7-17
Error Code > Error Code > Error Code Details
Error Code > Error Code > Error Code Details
Code
Detail
Code
Location
Item
Description
E110 0020 05
Title
Error in scanner motor (Drive fails to start.)
Description
of detection
When PLOCK signal cannot be detected during the BD
rotation of polygon scanner (either the PLOCK signal cannot
be detected within 7.5 sec from startup or PLOCK signal
cannot be detected for 1 sec continuously after VLOCK signal
is detected during FG rotation and PLOCK signal is detected
during BD rotation.).
Measures 1. Check the connector.
2. Replace the laser scanner unit.
3. Replace the DC controller PCB.
E110 0021 05
Title
Error in scanner motor (Revolution fails to reach the specified
value.)
Description
of detection
When PLOCK signal cannot be detected during the BD
rotation of polygon scanner (either the PLOCK signal cannot
be detected within 7.5 sec from startup or PLOCK signal
cannot be detected for 1 sec continuously after VLOCK signal
is detected during FG rotation and PLOCK signal is detected
during BD rotation.).
Measures 1. Check the connector.
2. Replace the laser scanner unit.
3. Replace the DC controller PCB.
E110 0022 05
Title
Error in scanner motor (BD detection fails.)
Description
of detection
When PLOCK signal cannot be detected during the BD
rotation of polygon scanner (either the PLOCK signal cannot
be detected within 7.5 sec from startup or PLOCK signal
cannot be detected for 1 sec continuously after VLOCK signal
is detected during FG rotation and PLOCK signal is detected
during BD rotation.).
Measures 1. Check the connector.
2. Replace the laser scanner unit.
3. Replace the DC controller PCB.
E110 0023 05
Title
Error in scanner motor (Detection fails after BD detection.)
Description
of detection
When PLOCK signal cannot be detected during the BD
rotation of polygon scanner (either the PLOCK signal cannot
be detected within 7.5 sec from startup or PLOCK signal
cannot be detected for 1 sec continuously after VLOCK signal
is detected during FG rotation and PLOCK signal is detected
during BD rotation.).
Measures 1. Check the connector.
2. Replace the laser scanner unit.
3. Replace the DC controller PCB.
Code
Detail
Code
Location
Item
Description
E110 0025 05
Title
Error in scanner motor (Rotation accuracy error during phase
control)
Description
of detection
When PLOCK signal cannot be detected during the BD
rotation of polygon scanner (either the PLOCK signal cannot
be detected within 7.5 sec from startup or PLOCK signal
cannot be detected for 1 sec continuously after VLOCK signal
is detected during FG rotation and PLOCK signal is detected
during BD rotation.).
Measures 1. Check the connector.
2. Replace the laser scanner unit.
3. Replace the DC controller PCB.
E110 0026 05
Title
Error in scanner motor (Error after phase lock)
Description
of detection
When PLOCK signal cannot be detected during the BD
rotation of polygon scanner (either the PLOCK signal cannot
be detected within 7.5 sec from startup or PLOCK signal
cannot be detected for 1 sec continuously after VLOCK signal
is detected during FG rotation and PLOCK signal is detected
during BD rotation.).
Measures 1. Check the connector.
2. Replace the laser scanner unit.
3. Replace the DC controller PCB.
E184 0301 05
Title
Error in active registration unit
Description
of detection
Home position of the pre-registration separation motor (M23)
cannot be detected.
Measures 1. Check the connector.
2. Replace the pre-registration roller separation HP sensor
(PS43).
3. Replace the pre-registration separation motor (M23).
4. Replace the registration/duplexing driver PCB (PCB4).
E184 0302 05
Title
Error in active registration unit
Description
of detection
Home position of the Skew correction motor 1 (M24) cannot
be detected.
Measures 1. Check the connector.
2. Replace the skew correction roller HP sensor (front) (PS55).
3. Replace the Skew correction motor 1 (M24).
4. Replace the registration/duplexing driver PCB (PCB4).
E184 0303 05
Title
Error in active registration unit
Description
of detection
Home position of the Skew correction motor 2 (M25) cannot
be detected.
Measures 1. Check the connector.
2. Replace the skew correction roller HP sensor (rear) (PS56).
3. Replace the Skew correction motor 2 (M25).
4. Replace the registration/duplexing driver PCB (PCB4).
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...