Parts Replacement and Cleaning > Periodic Replacing Parts, Durable Parts, Cleaning Parts > Removing Secondary Transfer Inner Roller
Parts Replacement and Cleaning > Periodic Replacing Parts, Durable Parts, Cleaning Parts > Removing Secondary Transfer Inner Roller
Removing Secondary Transfer Inner Roller
<Preparation>
1) Open the Front Left Cover and the Front Right
Cover.
2) Remove Process Unit Cover.
3) Pull Out ITB Unit.
4) Remove ITB Cleaning Unit.
5) Remove Patch Sensor Unit.
6) Remove ITB.
1) Loosen the screw and remove the secondary transfer inner roller unit (including the secondary
transfer mounting plate).
• 1 screw
Secondary transfer
inner roller unit
Screw
F-4-453
Caution :
Be careful not to touch the surface of secondary transfer inner roller because it
may cause the image failure.
F-4-454
2) Remove the secondary transfer inner roller.
Secondary transfer inner roller
F-4-455