R5909934 /00
E2 Lite and EC-40
93
Image 6-19: Configuration menu, Adjustment area, Output
The unit will query the connected device on its output for a preferred EDID and try to assign that as the output
resolution and frame rate. If no devices are connected, a standard HD resolution with the native rate of the
EMP is assigned as frame rate.
Next to the configuration name is the name of the Destination where the output is assigned. If the Output is not
assigned to any Destination, then the name will be
“
N/A
”
.
The software by default names outputs as
“
Output 1, 2, 3...
”
The user can rename each output by
double clicking on the name and type in the new name in the blue box.
How to add Output
Outputs configurations can be added manually to unassigned connectors.
1.
Click on the
Add Output
button.
The
Add Output
button is replaced by the
Done Adding
button (highlighted in blue).
2.
In the System diagram area, click on the connector(s) that need to be assigned.
Connector(s) is immediately highlighted in blue.
3.
The selection is completed by clicking the
Done Adding
button that is highlighted in blue.
A new Output is added in the output list.
How to delete Output
1.
Click on the
Delete Output(s)
button
The
Delete Output(s)
button is replaced by the
Delete Selected
button (highlighted in red).
2.
Click on the corresponding connector in the graphical area.
or
click in the
“
x
”
on the right hand side in the output configuration list.
Connector(s) is immediately highlighted in blue.
3.
The deletion is completed by clicking the
Delete Selected
button.
Multiple connector configurations can be selected to be deleted together.
Summary of Contents for Event Master E2 Lite
Page 1: ...ENABLING BRIGHT OUTCOMES User s Guide E2 Lite and EC 40...
Page 10: ...R5909934 00 E2 Lite and EC 40 10...
Page 14: ...R5909934 00 E2 Lite and EC 40 14 Introduction...
Page 18: ...R5909934 00 E2 Lite and EC 40 18 Safety...
Page 32: ...R5909934 00 E2 Lite and EC 40 32 General...
Page 46: ...R5909934 00 E2 Lite and EC 40 46 Hardware orientation...
Page 168: ...R5909934 00 E2 Lite and EC 40 168 EM GUI orientation...
Page 208: ...R5909934 00 E2 Lite and EC 40 208 Controller Orientation...
Page 214: ...R5909934 00 E2 Lite and EC 40 214 Controller Configuration...
Page 220: ...R5909934 00 E2 Lite and EC 40 220 Controller Operation...
Page 284: ...R5909934 00 E2 Lite and EC 40 284 E2 Lite Maintenance...
Page 289: ...289 R5909934 00 E2 Lite and EC 40 Environmental Information 15...
Page 300: ...R5909934 00 E2 Lite and EC 40 300 Specifications...
Page 316: ...R5909934 00 E2 Lite and EC 40 316 Remote Control Protocol...
Page 317: ...317 R5909934 00 E2 Lite and EC 40 Troubleshooting C...
Page 320: ...R5909934 00 E2 Lite and EC 40 320 Troubleshooting...