R5909934 /00
E2 Lite and EC-40
63
Image 5-31
The following attributes constitute a factory default condition:
•
The
Status
Menu is shown in the display screen.
•
All custom configurations are deleted.
The
Factory Reset
Menu provides two options for restoring factory default settings:
•
Factory Reset
—
If you use this option, all of your system configuration are deleted. Settings will be
restored to the original factory defaults.
•
Factory Reset, Save IP
—
This option performs a factory reset, but retains the IP address of the unit.
It is advisable to clear all saved configurations when you use the Event Master unit for the first time,
or when returning an unit from an event.
Restoring all factory settings
To restore all default settings to the Event Master unit, use the following procedure:
1.
Select
Factory Reset
from the
Setup
Menu.
The
Factory Reset
Menu appears.
2.
Select
Factory Reset
.
A prompt appears, asking if you want to clear all configurations.
3.
Press
SEL
.
The system turns off, then reboots.
If you press
ESC
to cancel the operation instead, your custom settings remain in place and you are returned to
the
Factory Reset
Menu.
Retaining the IP address when restoring factory settings
To restore default settings to the Event Master unit but retain the unit
’
s IP address, use the following
procedure:
1.
Select
Factory Reset
from the
Setup
Menu.
The
Factory Reset
Menu appears.
2.
Select
Factory Reset, Save IP
.
A prompt appears, asking if you want to clear all configurations.
3.
Press
SEL
to reset the system but save the IP address.
The system turns off, then reboots.
If you press
ESC
to cancel the operation instead, your custom settings remain in place and you are returned to
the
Factory Reset
Menu.
5.15 Firmware Upgrade
General
The Event Master unit provides two options for upgrading firmware:
•
Using the USB port on the front panel.
•
Using the Web Interface.
Summary of Contents for Event Master E2 Lite
Page 1: ...ENABLING BRIGHT OUTCOMES User s Guide E2 Lite and EC 40...
Page 10: ...R5909934 00 E2 Lite and EC 40 10...
Page 14: ...R5909934 00 E2 Lite and EC 40 14 Introduction...
Page 18: ...R5909934 00 E2 Lite and EC 40 18 Safety...
Page 32: ...R5909934 00 E2 Lite and EC 40 32 General...
Page 46: ...R5909934 00 E2 Lite and EC 40 46 Hardware orientation...
Page 168: ...R5909934 00 E2 Lite and EC 40 168 EM GUI orientation...
Page 208: ...R5909934 00 E2 Lite and EC 40 208 Controller Orientation...
Page 214: ...R5909934 00 E2 Lite and EC 40 214 Controller Configuration...
Page 220: ...R5909934 00 E2 Lite and EC 40 220 Controller Operation...
Page 284: ...R5909934 00 E2 Lite and EC 40 284 E2 Lite Maintenance...
Page 289: ...289 R5909934 00 E2 Lite and EC 40 Environmental Information 15...
Page 300: ...R5909934 00 E2 Lite and EC 40 300 Specifications...
Page 316: ...R5909934 00 E2 Lite and EC 40 316 Remote Control Protocol...
Page 317: ...317 R5909934 00 E2 Lite and EC 40 Troubleshooting C...
Page 320: ...R5909934 00 E2 Lite and EC 40 320 Troubleshooting...