System Native Rate (Hz)
: System native rate in Hz (Cycles in second). Available selections:
50
59.94
60
The native system rate needs to match the general frame rate in the event where the unit is used.
•
System Backup
: IP address of the backup system.
Enter the IP address of the backup unit, and press the "Sync" button to push the settings from the active
system to the backup system.
•
Genlock
: Selects the system genlock mode from the options
Freerun
,
Lock to External
, or
Lock to Unit
ID
.
•
Genlock Status
: Reports the system
’
s genlock mode status: Locked or not Locked.
•
H Offset
: The H sync can be offset to match a Genlock situation. Adjustment in ms.
•
V Offset
: The V sync can be offset to match a Genlock situation. Adjustment in ms.
•
Master VP
: Reports the units IP address in the local network.
•
Unit ID
: Reports the units ID number. ID required to identify different units are acting as a single or linked
system in order to expand for Inputs, Outputs or Layers.
6.11 Configuration Menu > Adjustment area
General
Situated on the right hand side of the screen is the Adjustment area. In this area the user can define and
adjust unit specific parameters, inputs, outputs, multiviewer outputs and destination affected to the selected
system.
Description
There are 4 tabs in this area:
•
Input
: this tab provides a list of all the created
inputs. Here the user can create new entries by
associating them with input connectors. It is also in
this tab that the user can delete unused or
obsolete inputs.
•
Output/MVR
: the user can add or remove
program, auxiliary and multiviewer outputs in this
list.
•
Destination
: a destination is a location where the
user can route the output of Event Master series
processor (screens, widescreens, monitors etc.).
The user could assign the outputs that are created
in the previous tab to destinations, and deleted
unused or obsolete destinations
Always on top:
•
Adjustment
: in this tab the user performs
adjustments available for the selected item
(device, input, background, output, destination).
The content of this tab varies depending on the
selected item. Access to this area is achieved from
the
System diagram area
(click on device or on a
destination) or in one of the tabs of the
Adjustment area
(input, background, output,
destination) .
The following sections describe how to perform the configuration of each part of the system in detail:
•
Configuration Menu > Adjustment > Unit Configuration
, page 79
Summary of Contents for Event Master E2 Lite
Page 1: ...ENABLING BRIGHT OUTCOMES User s Guide E2 Lite and EC 40...
Page 10: ...R5909934 00 E2 Lite and EC 40 10...
Page 14: ...R5909934 00 E2 Lite and EC 40 14 Introduction...
Page 18: ...R5909934 00 E2 Lite and EC 40 18 Safety...
Page 32: ...R5909934 00 E2 Lite and EC 40 32 General...
Page 46: ...R5909934 00 E2 Lite and EC 40 46 Hardware orientation...
Page 168: ...R5909934 00 E2 Lite and EC 40 168 EM GUI orientation...
Page 208: ...R5909934 00 E2 Lite and EC 40 208 Controller Orientation...
Page 214: ...R5909934 00 E2 Lite and EC 40 214 Controller Configuration...
Page 220: ...R5909934 00 E2 Lite and EC 40 220 Controller Operation...
Page 284: ...R5909934 00 E2 Lite and EC 40 284 E2 Lite Maintenance...
Page 289: ...289 R5909934 00 E2 Lite and EC 40 Environmental Information 15...
Page 300: ...R5909934 00 E2 Lite and EC 40 300 Specifications...
Page 316: ...R5909934 00 E2 Lite and EC 40 316 Remote Control Protocol...
Page 317: ...317 R5909934 00 E2 Lite and EC 40 Troubleshooting C...
Page 320: ...R5909934 00 E2 Lite and EC 40 320 Troubleshooting...