R5909934 /00
E2 Lite and EC-40
58
Setting a static IP Address
When a DHCP server is not available, you can set the Event Master unit
’
s IP address, using the
Set IP
submenu shown in the following illustration.
Image 5-18: Set IP Submenu (sample)
How to set a static IP address?
1.
Ensure that the
DHCP
setting is
Off
.
2.
From your network administrator, obtain a valid IP address, including subnet and gateway.
3.
On the
Ethernet
submenu, select
Set Static IP
.
4.
On the
Set IP
submenu, select
SUB
(net). The last character in the first field becomes available, as indicated
by the empty field and an underscore.
Note:
You must change the
SUB
parameter before editing either of the other parameters.
5.
Turn the
ADJUST
knob to change the first value. As you continue turning the knob, you can change all three
values in this field. Values range from
000
to
255
in all four fields.
6.
Press
SEL
to accept your change in the first field. The last character in the next field becomes available.
7.
Continue until you have created the subnet value you want. Press
SEL
.
8.
Make similar changes in the
GW
and
IP
fields.
9.
Press
SEL
to accept your final change.
If you press
ESC
at any time before accepting your final change, all your edits will be removed, and
the original values restored.
5.10 System menu > VFD brightness (display
brightness)
General
The
VFD Brightness
submenu adjust the intensity of the front panel vacuum fluorescent display (VFD)
screen. The adjustment range is
+0
to
+6
, with
+6
being the brightest. The default setting is
+3
.
5.11 System menu > Diagnostics
General
The following illustration shows the
Diagnostics
submenu, which you access from the
System
menu.
Summary of Contents for Event Master E2 Lite
Page 1: ...ENABLING BRIGHT OUTCOMES User s Guide E2 Lite and EC 40...
Page 10: ...R5909934 00 E2 Lite and EC 40 10...
Page 14: ...R5909934 00 E2 Lite and EC 40 14 Introduction...
Page 18: ...R5909934 00 E2 Lite and EC 40 18 Safety...
Page 32: ...R5909934 00 E2 Lite and EC 40 32 General...
Page 46: ...R5909934 00 E2 Lite and EC 40 46 Hardware orientation...
Page 168: ...R5909934 00 E2 Lite and EC 40 168 EM GUI orientation...
Page 208: ...R5909934 00 E2 Lite and EC 40 208 Controller Orientation...
Page 214: ...R5909934 00 E2 Lite and EC 40 214 Controller Configuration...
Page 220: ...R5909934 00 E2 Lite and EC 40 220 Controller Operation...
Page 284: ...R5909934 00 E2 Lite and EC 40 284 E2 Lite Maintenance...
Page 289: ...289 R5909934 00 E2 Lite and EC 40 Environmental Information 15...
Page 300: ...R5909934 00 E2 Lite and EC 40 300 Specifications...
Page 316: ...R5909934 00 E2 Lite and EC 40 316 Remote Control Protocol...
Page 317: ...317 R5909934 00 E2 Lite and EC 40 Troubleshooting C...
Page 320: ...R5909934 00 E2 Lite and EC 40 320 Troubleshooting...