Communications and File Transfers
162
NetLinx Studio (v2.4 or higher)
b.
Click the
Communication Settings
button to access the Communication Settings dialog.
c.
Select
Virtual NetLinx Master
as the Transport Connection Option.
d.
Click
OK
to close this dialog.
e.
Click
OK
to close the Master Communication Settings dialog.
Configuring NetLinx Studio for Virtual NetLinx Master Transfers
1.
Select
Settings > Master Communications
to open the Master Communication Settings
dialog.
2.
Make a selection in the
Available Systems
list to specify the scope of this communication
setting:
Select
<No Active System-Default Settings>
to set Virtual NetLinx Master as the
default communication setting.
To set Virtual NetLinx Master as the communication setting for a particular system in the
active project, select one of the Systems listed under NetLinx Project.
3.
Click
Communication Settings
to access the Communication Settings dialog.
4.
Verify that
NetLinx Master
is selected as the
Platform Selection
, and select
Virtual NetLinx
Master
as the
Transport Connection Option
.
5.
Click
Edit Settings
to access the Virtual NetLinx Master Settings dialog.
6.
The
System Number
field is set to
1
by default. Assuming that the actual NetLinx Master is
set to
0
(via the System Properties dialog - System ID field), this default setting will work.
However, if you have designated any other number as the System ID, be sure to set this System
Number to a different number than the System ID, to avoid a conflict with the actual NetLinx
Master (range = 1-65535).
Transferring Files Using A Virtual Netlinx Master Usb Connection
To use Virtual NetLinx Master to transfer TPDesign4 panel (.TP4) files, NetLinx Firmware (.KIT)
files or IR files directly to a MVP-7500, MVP-8400 or NXD/T-CV7 panel via USB:
1.
Select
Tools > File Transfer
to open the File Transfer dialog (open to the Send tab).
2.
Click the
Add
button to open the Select Files for File Transfer dialog.
3.
Click the
Other
tab, and select the type of file you want to transfer (only IRL/IRV, TP4 or IRN
files can be transferred via a Virtual NetLinx Master connection).
4.
Click the
Add
button. This invokes the Open dialog, where you can locate and select the file
you want to transfer.
As indicated in the Virtual NetLinx Master dialog, changes made to the system
number field will not take effect until all communications are stopped and restarted.
Verify that Virtual NetLinx Master is selected as the Transport Connection Option in
the Communication Settings dialog.
Summary of Contents for NETLINX STUDIO V2.4
Page 1: ...instruction manual Software NetLinx Studio v2 4 or higher ...
Page 16: ...NetLinx Studio v2 4 or higher 4 NetLinx Studio v2 4 or higher ...
Page 32: ...The NetLinx Studio v2 4 Work Area 20 NetLinx Studio v2 4 or higher ...
Page 44: ...Working With Workspace Files 32 NetLinx Studio v2 4 or higher ...
Page 88: ...Working With Systems and System Files 76 NetLinx Studio v2 4 or higher ...
Page 118: ...Programming 106 NetLinx Studio v2 4 or higher ...
Page 152: ...Working With Online Devices 140 NetLinx Studio v2 4 or higher ...