Communications and File Transfers
149
NetLinx Studio (v2.4 or higher)
transport connection type specified. These instructions in these topics assume that the physical link
between the PC running NetLinx Studio and the NetLinx master is established.
1.
Select
Settings > Master Communication Settings
to open the Master Communication
Settings dialog.
2.
Click
Communication Settings
to access the Communication Settings dialog.
3.
Select
Axcess Master
as the Platform Selection.
4.
Select
Modem
as the Transport Connection Option.
5.
Click
Edit Settings
to open the Modem Settings dialog.
6.
Select a COM port and specify the communication settings for modem communications. The
default settings are:
7.
Click
OK
to return to the Communication Settings dialog.
8.
Click
OK
to return to the Master Communication Settings dialog.
9.
Click
OK
to close the Master Communications dialog.
10.
In the online tree (displayed in the Online Tree tab of the Workspace window), click
Display
to
open the Online Tree sub-menu, and select
Refresh Network
to refresh the online tree display.
11.
Double-click the System icon to expand the tree to show the Axcess master.
File Transfer Operations
NetLinx Studio supports asynchronous communications (send and receive to and from the bus on
all available communications ports simultaneously). You can send and receive both Axcess and
NetLinx Source Code files to and from the Master Controller or bus device.
Axcess or NetLinx Source Code files (.AXS) can be sent to the Master Controller, or
other control devices on the bus. Source code files must be successfully compiled before
they can be sent.
Touch Panel UI files created in TPDesign3 (.TPD) are sent directly to wired Touch Panels
on the bus via an AXlink/serial connection where the Device ID = 0.
Touch Panel UI files created in TPDesign4 (.TP4) are sent to the Master, either serially or
over TCP/IP. G4 panels are connected to the Masters via TCP/IP and cannot be sent over
AXlink. You can choose to include buttons and pages only, or include fonts, bitmaps and/
or icons in the transfer.
KeyPad UI files (.KPD) are sent to a NetLinx Master.
Comm Port
COM1
Baud Rate
38400
Data Bits
8
Parity
None
Stop Bits
1
Flow Control
None
Phone Number
Enter the telephone number of the master.
Summary of Contents for NETLINX STUDIO V2.4
Page 1: ...instruction manual Software NetLinx Studio v2 4 or higher ...
Page 16: ...NetLinx Studio v2 4 or higher 4 NetLinx Studio v2 4 or higher ...
Page 32: ...The NetLinx Studio v2 4 Work Area 20 NetLinx Studio v2 4 or higher ...
Page 44: ...Working With Workspace Files 32 NetLinx Studio v2 4 or higher ...
Page 88: ...Working With Systems and System Files 76 NetLinx Studio v2 4 or higher ...
Page 118: ...Programming 106 NetLinx Studio v2 4 or higher ...
Page 152: ...Working With Online Devices 140 NetLinx Studio v2 4 or higher ...