CAL<n>:OUTP:VOLT:DAC 19000
12. Let the output settle and measure the voltage with a high precision voltmeter;
this is value 2.
13.
Enter the actual output voltage value of the second calibration point:
CAL<n>:OUTP:VOLT:FIVEPOINT 2 <value 2>
14.
Program the output of the third calibration point by sending the following
command string from the computer:
CAL<n>:OUTP:VOLT:DAC 32000
15. Let the output settle and measure the voltage with a high precision voltmeter;
this is value 3.
16.
Enter the actual output voltage value of the third calibration point:
CAL<n>:OUTP:VOLT:FIVEPOINT 3 <value 3>
17.
Program the output of the fourth calibration point by sending the following
command string from the computer:
CAL<n>:OUTP:VOLT:DAC 45000
18. Let the output settle and measure the voltage with a high precision voltmeter;
this is value 4.
19.
Enter the actual output voltage value of the fourth calibration point:
CAL<n>:OUTP:VOLT:FIVEPOINT 4 <value 4>
20.
Program the output of the fifth calibration point by sending the following
command string from the computer:
CAL<n>:OUTP:VOLT:DAC 62250
21. Let the output settle and measure the voltage with a high precision voltmeter;
this is value 5.
22.
Enter the actual output voltage value of the fifth calibration point:
CAL<n>:OUTP:VOLT:FIVEPOINT 5 <value 5>
23.
To review entered data for five
–point voltage calibration, issue the following
query:
Summary of Contents for Sorensen Asterion DC ASM
Page 1: ...M330517 01 Rev C Asterion DC Multioutput Series Programming Manual...
Page 6: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C v SAFETY SYMBOLS...
Page 145: ...Asterion DC Multioutput Series Programming Manual 13 128 M330517 01 Rev C CAL n LOCK...
Page 162: ...M330461 01 Rev C 14 145...