Asterion DC Multioutput Series
Programming Manual
M330517-01 Rev C
10-67
Command
Description
*OPC
Enables the Operation Complete bit of the Standard Event Status
Register to be set when all pending operations are complete. See
section 10.2.2.
*RST
Resets the supply to its Power ON (PON) state.
Clears all status reporting data structures including the Status Byte,
Standard
Event
Status
Register,
and
Error
Queue.
The
STAT<n>:PROT:ENAB
(protection event enable register) is cleared by
this command; other enable registers are not cleared by this command.
*SRE <0+NR1>
Sets the value of the Service Request Enable Register, which
determines which bits in the Status Byte will cause a service request
from the device. See section on Status Byte for valid values.
*SRE?
Returns the integer value of the Service Request Enable Register. See
section on Status Byte for valid values. Values range from 0-63 or 128-
191.
Response: <0+NR1>
*STB?
Returns the integer value of the Status Byte with bit 6 representing the
Summary Status (SS) instead of RQS. The SS bit acts as a summary
bit for the Status Byte and indicates whether the device has at least
one reason to request service based on the MAV and the ESR bits.
See section on Status Byte for valid values. Values range from 0-255.
Response: <0+NR1>
Summary of Contents for Sorensen Asterion DC ASM
Page 1: ...M330517 01 Rev C Asterion DC Multioutput Series Programming Manual...
Page 6: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C v SAFETY SYMBOLS...
Page 145: ...Asterion DC Multioutput Series Programming Manual 13 128 M330517 01 Rev C CAL n LOCK...
Page 162: ...M330461 01 Rev C 14 145...