Asterion DC Multioutput Series
Programming Manual
M330517-01 Rev C
10-91
Command
Description
SCPI
CALibrate<n>:OUTPut:CURRent:GAIN
<NRf>
Sets the value of the gain for the
output current.
N
CALibrate<n>:OUTPut:CURRent:GAIN?
Returns the value of the gain for the
output current.
N
CALibrate<n>:OUTPut:CURRent:OFFSet
<NRf>
Sets the value of the offset for the
output current.
N
CALibrate<n>:OUTPut:CURRent:OFFSet?
Returns the value of the offset for
the output current.
N
CALibrate<n>:OUTPut:CURRent:EXTV:OFF
Set <NRf>
Sets the calibration Offset point for
current programming from external
voltage source
N
CALibrate<n>:OUTPut:CURRent:EXTV:OFF
Set?
Returns the calibration Offset point
of current programming from
external voltage source
N
CALibrate<n>:OUTPut:CURRent:EXTV:FSC
<NRf>
Sets the calibration full-scale point
for current programming from
external voltage source
N
CALibrate<n>:OUTPut:CURRent:EXTV:FSC
?
Returns the calibration full -scale
point of current programming from
external voltage source
N
CALibrate<n>:OUTPut:CURRent:EXTI:OFF
Set <NRf>
Sets the calibration Offset point for
current programming from external
resistance source
N
CALibrate<n>:OUTPut:CURRent:EXTI:OFF
Set?
Returns the calibration Offset point
of current programming from
external resistance source
N
CALibrate<n>:OUTPut:CURRent:EXTI:FSC
<NRf>
Sets the calibration full-scale point
for current programming from
external resistance source
N
CALibrate<n>:OUTPut:CURRent:EXTI:FSC
?
Returns the calibration Offset point
of current programming from
external resistance source
N
CALibrate<n>:OUTPut:CURRent:MON:OFFS
ET <NRf>
Sets the calibration Offset point for
current monitor signal
N
CALibrate<n>:OUTPut:CURRent:MON:FSC
<NRf>
Sets the calibration full-scale point
for current monitor signal
N
CALibrate<n>:OUTPut:VOLTage:CALCulat
e
Calculates the value of the gain and
offset for output voltage.
N
CALibrate<n>:OUTPut:VOLTage:DAC
<NR1>
Sets the output of the output voltage
D/A converter.
N
CALibrate<n>:OUTPut:VOLTage:FIVEPOIN
T <1|2|3|4|5> <NRf>
Sets output voltage value for each
calibration point (1-5)
N
CALibrate<n>:OUTPut:VOLTage:FIVEPOIN
T?
Returns the entered values for 5-
point calibration.
N
CALibrate<n>:OUTPut:VOLTage:GAIN
<NRf>
Sets the value of the gain for the
output voltage.
N
CALibrate<n>:OUTPut:VOLTage:GAIN?
Returns the value of the gain for the
output voltage.
N
CALibrate<n>:OUTPut:VOLTage:OFFSet
<NRf>
Sets the value of the offset for the
output voltage.
N
CALibrate<n>:OUTPut:VOLTage:OFFSet?
Returns the value of the offset for
the output voltage.
N
Summary of Contents for Sorensen Asterion DC ASM