Asterion DC Multioutput Series
Programming Manual
10-66
M330517-01 Rev C
subsequent device read will return a value such as “33.000”. All queries are terminated
with a carriage return and line feed (0x0D 0x0A). When the power supply has nothing to
report, its output buffer will contain two ASCII characters: a carriage return and linefeed
(in decimal the values are: <13><10>).
IEEE 488.2 Common Command Subsystem
The following commands are common to all SCPI instruments and declared mandatory
by IEEE 488.2. In the following table, the power supply is defined as the “device” on the
GPIB bus.
Command
Description
*CLS
Clears all status reporting data structures including the Status Byte,
Standard
Event
Status
Register,
and
Error
Queue.
The
STAT<n>:PROT:ENAB
(protection event enable register) is cleared by
this command; other enable registers are not cleared by this command.
*ESE <0+NR1>
Sets the value of the Standard Event Status Enable Register that
determines which bits can be set in the Standard Event Status
Register. See section 10.2.2 for valid values.
*ESE?
Returns the integer value of the Standard Event Status Enable
Register. See section 10.2.2 for valid values.
Response:
<0+NR1>
*ESR?
Returns the integer value of the Standard Event Status Register. The
ESR and the Status Byte ESR bit are cleared. See section 10.2.2 for
valid values.
Response:
<0+NR1>
*IDN?
Returns the device identification as an ASCII string.
Response:
<Manufacturer>, <UUT model Configuration>, <serial
number>,<SC firmware version>, AIB firmware version>,<FPC
firmware version>
SC-System Controller
AIB- Analog Interface Board
FPC- Front Panel Controller
Example:
AMETEK programable power, ASA060200400C-
E010,1234,1.000,1.00,1.00
*IDN<n>?
Returns the Channel identification as an ASCII string.
Response:
<Manufacturer>, <UUT Channel Configuration>, <serial
number>,<SC firmware version>, AIB firmware version>,<FPC
firmware version>
SC-System Controller
AIB- Analog Interface Board
FPC- Front Panel Controller
Example:
AMETEK programable power, ASA200-17ARC-
E010,1234,1.000,1.00,1.00
Summary of Contents for Sorensen Asterion DC ASM
Page 1: ...M330517 01 Rev C Asterion DC Multioutput Series Programming Manual...
Page 6: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C v SAFETY SYMBOLS...
Page 145: ...Asterion DC Multioutput Series Programming Manual 13 128 M330517 01 Rev C CAL n LOCK...
Page 162: ...M330461 01 Rev C 14 145...