M330517-01 Rev C
10-60
Figure 10-1: Protection Condition and Protection Event Register
The SESR (Standard Event Service Register). Masking does
not
prevent events from
setting bits in the SESR. This facilitates polling as a means of detecting these events,
since the SESR can be polled (read) using the *ESR? command, irrespective of the bits
set or not set in the Standard Event Status Enable Register.
The SCPI Status Byte. Read using either the
*STB? command, or the GPIB serial poll operation.
The SESER (Standard Event Status Enable Register). This
register is read using the *ESE? SCPI query command. This
register is written to using the *ESE <value> command. A “1” in
the appropriate bit location enables that corresponding bit from
the SESR to pass through to the input of the OR gate to be
included in the SESR summary bit (bit 5) in the SCPI Status Byte.
The Service Request Enable Register (SRER).
Used to enable which Status Byte bits can affect the
service request bit. *SRE? reads. *SRE <value> writes.
Seven bit-wise logical AND
operations
Eight bit-wise logical AND
operations
The Protection Enable Register. Readable using the STAT:PROT:ENAB? query
command. Writable using the STAT:PROT:ENAB <value> command. Used to select
what fault events could set a bit in the Fault Register. Certain faults can occur even
if they are not enabled. This is because the Protection Enable Register merely filters
which events are allowed to affect the Fault Register, not whether those events can
occur or not.
Protection Condition Register
–
readable using
STAT:PROT:COND? query command
Fault Register (also called the Protection Event Register).
Readable using the STAT:PROT:EVEN? Query.
command. Bit 21 to 31 are not used.
Bit
Hex Value
Description
0
0x01
Not Used
1
0x02
Protection Event Flag
2
0x04
Error/Event Queue Message Avail.
3
0x08
Questionable Status (Not Used)
4
0x10
Message Available
5
0x20
Standard Event Status Register
6
0x40
RQS/SS Service Request Bit
7
0x80
Operation Status Flag (Not Used)
Summary of Contents for Sorensen Asterion DC ASM
Page 1: ...M330517 01 Rev C Asterion DC Multioutput Series Programming Manual...
Page 6: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C v SAFETY SYMBOLS...
Page 145: ...Asterion DC Multioutput Series Programming Manual 13 128 M330517 01 Rev C CAL n LOCK...
Page 162: ...M330461 01 Rev C 14 145...