Asterion DC Multioutput Series
Programming Manual
M330517-01 Rev C
10-79
:DHCPMODE <boolean>
:DHCPMODE?
:DNS <string>
:DNS?
:GATE <string>
:GATE?
:HOST <string>
:HOST?
:IP <string>
:IP?
:LANLED <boolean>
:LANLED?
:MAC?
:MASK <string>
:MASK?
:NETBUTTON <string>
:PORT <NRf>
:PORT?
:TERM <NRf>
:TERM?
10.8.2
SYSTEM SCPI Command Reference
The letter “C” in the “SCPI” column means that the command syntax is SCPI compliant;
an “N” in the “SCPI” column means that the command syntax is not part of the SCPI
definition.
Command
Description
SCPI
SYSTem:ERRor?
Queries Error Queue for next error/event entry (first in, first out).
Entries contain an error number and descriptive text. A 0-return
value indicates no error occurred; negative numbers are
reserved by SCPI. The maximum return string length is 255
characters. The queue holds up to 10 error/entries. All entries
are cleared by the *CLS command.
C
SYSTem:LOCAL <boolean>
Forces the supply to local or remote state.
<ON> or <1> sets operation to local mode.
<OFF> or <0> sets the operation to remote mode.
N
SYSTem:LOCAL?
Returns ON or 1 if in local mode.
Returns OFF or 0 if in remote mode.
N
SYSTem:PROGDELAY:REFrence
<1|2|3>
Sets the Reference channel of output ON or OFF delay. Valid
arguments are :
1 (sets channel 1 as reference channel for output ON or OFF
delay), or
2 (sets channel 2 as reference channel for output ON or OFF
delay), or
3 (sets channel 3 as reference channel for output ON or OFF
delay).
N
SYSTem:PROGDELAY:REFerence?
Returns the programed reference channel for output ON or OFF
delay.
N
SYSTem:PROGDELAY:ENABLE <1>
<2> <3>
Configures the channels to turn ON or OFF the output, on Output
ON or OFF Delay Feature. Including Refence channel, Minimum
2 channels need to be Enabled.
N
Summary of Contents for Sorensen Asterion DC ASM
Page 1: ...M330517 01 Rev C Asterion DC Multioutput Series Programming Manual...
Page 6: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C v SAFETY SYMBOLS...
Page 145: ...Asterion DC Multioutput Series Programming Manual 13 128 M330517 01 Rev C CAL n LOCK...
Page 162: ...M330461 01 Rev C 14 145...