![Agilent Technologies DSO-X 4022A User Manual Download Page 390](http://html1.mh-extra.com/html/agilent-technologies/dso-x-4022a/dso-x-4022a_user-manual_2868638390.webp)
390
Agilent InfiniiVision 4000 X-Series Oscilloscopes User's Guide
23
CAN/LIN Triggering and Serial Decode
3
Press the
Trigger:
softkey; then, turn the Entry knob to select the trigger
condition:
•
SOF - Start of Frame
— The oscilloscope triggers at the start of a frame.
•
Remote Frame ID (RTR)
— The oscilloscope triggers on remote frames
with the specified ID. Press the
Bits
softkey to select the ID.
•
Data Frame ID (~RTR)
— The oscilloscope will trigger on data frames
matching the specified ID. Press the
Bits
softkey to select the ID.
•
Remote or Data Frame ID
— The oscilloscope will trigger on remote or
data frames matching the specified ID. Press the
Bits
softkey to select
the ID.
•
Data Frame ID and Data
— The oscilloscope will trigger on data frames
matching the specified ID and data. Press the
Bits
softkey to select
the ID and set up the number of data bytes and values.
•
Error Frame
— The oscilloscope will trigger on CAN active error frames.
•
All Errors
— The oscilloscope will trigger when any form error or
active error is encountered.
•
Acknowledge Error
— The oscilloscope will trigger when the
acknowledge bit is recessive (high).
•
Overload Frame
— The oscilloscope will trigger on CAN overload
frames.
4
If you select a condition that lets you trigger on ID or data values, use
the
Bits
softkey and the CAN Bits Menu to specify those values.
For details about using the CAN Bits Menu softkeys, press and hold the
softkey in question to display the built- in help.
You can use the
Zoom
mode for easier navigation of the decoded data.
N O T E
If the setup does not produce a stable trigger, the CAN signal may be slow enough that the
oscilloscope is AutoTriggering. Press the [Mode/Coupling] key, then press the Mode
softkey to set the trigger mode from Auto to Normal.
Summary of Contents for DSO-X 4022A
Page 1: ...s1 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide...
Page 8: ...8 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide...
Page 26: ...26 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide...
Page 62: ...62 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 1 Getting Started...
Page 78: ...78 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Page 118: ...118 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 4 Math Waveforms...
Page 142: ...142 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Page 148: ...148 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Page 156: ...156 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 8 Display Settings...
Page 204: ...204 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 10 Triggers...
Page 240: ...240 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 13 Cursors...
Page 270: ...270 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 14 Measurements...
Page 286: ...286 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Page 328: ...328 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 19 Print Screens...
Page 362: ...362 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 21 Web Interface...
Page 366: ...366 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 21 Web Interface...