![Agilent Technologies DSO-X 4022A User Manual Download Page 154](http://html1.mh-extra.com/html/agilent-technologies/dso-x-4022a/dso-x-4022a_user-manual_2868638154.webp)
154
Agilent InfiniiVision 4000 X-Series Oscilloscopes User's Guide
8
Display Settings
2
Press the
Intensity
softkey; then, turn the Entry knob
to change the
intensity of the displayed grid.
The intensity level is shown in the
Intensity
softkey and is adjustable from
0 to 100%.
Each major vertical division in the grid corresponds to the vertical
sensitivity shown in the status line at the top of the display.
Each major horizontal division in the grid corresponds to the time/div
shown in the status line at the top of the display.
To display waveforms as vectors or dots
Agilent InfiniiVision 4000 X- Series oscilloscopes are designed to operate
optimally with vectors (connect the dots) on. This mode produces the
most insightful waveforms for most situations.
On the 1 GHz and 1.5 GHz bandwidth models, you can disable vectors to
view just waveform data points.
To disable or re- enable vectors:
1
Press
[Display] > More
.
2
Press
Vectors
.
When enabled,
Vectors
draws a line between consecutive waveform data
points.
•
Vectors give an analog look to a digitized waveform. Complex analog
signals like video and modulated signals show analog- like intensity
information with vectors on.
•
Vectors allow you to see steep edges on waveforms, such as square
waves.
•
Vectors allow subtle detail of complex waveforms to be viewed, much
like an analog oscilloscope trace, even when the detail is just a small
number of pixels in size.
You may want to turn vectors off when highly complex or multivalued
waveforms are displayed. Turning vectors off may aid the display of
multivalued waveforms such as eye diagrams.
Summary of Contents for DSO-X 4022A
Page 1: ...s1 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide...
Page 8: ...8 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide...
Page 26: ...26 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide...
Page 62: ...62 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 1 Getting Started...
Page 78: ...78 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Page 118: ...118 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 4 Math Waveforms...
Page 142: ...142 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Page 148: ...148 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Page 156: ...156 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 8 Display Settings...
Page 204: ...204 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 10 Triggers...
Page 240: ...240 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 13 Cursors...
Page 270: ...270 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 14 Measurements...
Page 286: ...286 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Page 328: ...328 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 19 Print Screens...
Page 362: ...362 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 21 Web Interface...
Page 366: ...366 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 21 Web Interface...