![Agilent Technologies DSO-X 4022A User Manual Download Page 310](http://html1.mh-extra.com/html/agilent-technologies/dso-x-4022a/dso-x-4022a_user-manual_2868638310.webp)
310
Agilent InfiniiVision 4000 X-Series Oscilloscopes User's Guide
18
Save/Recall (Setups, Screens, Data)
•
8-bit Bitmap image (*.bmp)
— The complete screen image in a reduced
color (8- bit) bitmap format. See
"To save BMP or PNG image files"
on
page 311.
•
24-bit Bitmap image (*.bmp)
— The complete screen image in a 24- bit
color bitmap format. See
"To save BMP or PNG image files"
on
page 311.
•
24-bit image (*.png)
— The complete screen image in a 24- bit color PNG
format that uses lossless compression. Files are much smaller than
the BMP format. See
"To save BMP or PNG image files"
on page 311.
•
CSV data (*.csv)
— This creates a file of comma- separated values of all
displayed channels and math waveforms. This format is suitable for
spreadsheet analysis. See
"To save CSV, ASCII XY, or BIN data
files"
on page 312.
•
ASCII XY data (*.csv)
— This creates separate files of comma- separated
values for each displayed channel. This format is also suitable for
spreadsheets. See
"To save CSV, ASCII XY, or BIN data files"
on
page 312.
•
Reference Waveform data (*.h5)
— Saves waveform data in a format that
can be recalled to one of the oscilloscope's reference waveform
locations. See
"To save reference waveform files to a USB storage
device"
on page 315.
•
Binary data (*.bin)
— This creates a binary file, with a header, and data
in the form of time and voltage pairs. This file is much smaller than
the ASCII XY data file. See
"To save CSV, ASCII XY, or BIN data
files"
on page 312.
•
Lister data (*.csv)
— This is a CSV format file containing serial decode
row information with commas separating the columns. See
"To save
Lister data files"
on page 315.
•
Mask (*.msk)
— This creates a mask file in an Agilent proprietary
format that can be read by Agilent InfiniiVision oscilloscopes. A mask
data file includes some oscilloscope setup information, but not all
setup information. To save all setup information including the mask
data file, choose "Setup (*.scp)" format instead. See
"To save
masks"
on page 316.
•
Arbitrary Waveform data (*.csv)
— This creates a file of comma- separated
values for the arbitrary waveform points' time and voltage values. See
"To save arbitrary waveforms"
on page 316.
Summary of Contents for DSO-X 4022A
Page 1: ...s1 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide...
Page 8: ...8 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide...
Page 26: ...26 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide...
Page 62: ...62 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 1 Getting Started...
Page 78: ...78 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Page 118: ...118 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 4 Math Waveforms...
Page 142: ...142 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Page 148: ...148 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Page 156: ...156 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 8 Display Settings...
Page 204: ...204 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 10 Triggers...
Page 240: ...240 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 13 Cursors...
Page 270: ...270 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 14 Measurements...
Page 286: ...286 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Page 328: ...328 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 19 Print Screens...
Page 362: ...362 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 21 Web Interface...
Page 366: ...366 Agilent InfiniiVision 4000 X Series Oscilloscopes User s Guide 21 Web Interface...