Configuration
53
Type
Explanation
exiting the premises, closing this zone can also be used to end the exit delay. This detector can be
used as a "Normal Alarm" when the system is armed internally.
Entry Route
This zone does not trigger an alarm if a "Final Door" zone has previously activated the entry delay
time. An immediate alarm is triggered if no entry delay has previously been activated. Use this zone
type for a motion detector in the entrance area, directed at the entrance door (which is fitted with a
magnetic contact), for example. This detector can be used as a "Final Door" detector when the sys-
tem is armed internally. It is possible to exit the configuration menu when this zone is open.
Technical Alarm
A "Technical Alarm" zone triggers an alarm and communication when the system is disarmed.
When the system is armed, only communication is sent; no alarm is triggered. If an alarm is trig-
gered in this zone when the system is armed, it is displayed on the alarm panel when the system is
disarmed. Use this zone type for flood detectors, for example. The wireless info module and the
wireless indoor siren signal technical alarms with beeps, like the alarm panel.
Key Switch (Mo-
ment.)
Teach in a (momentary) key switch on the wireless alarm panel. A change to this zone changes the
status of the alarm panel from set to unset, or from unset to set (after the delay time has expired).
Key Switch
(Latched)
A (latched) key switch can be connected to the alarm panel. A change to this zone changes the
status of the alarm panel from set to unset, or from unset to set (after the delay time has expired).
Note that the alarm panel is only operated via the key switch. When the status is not known, e.g.
when the key switch is closed but disabled on the control device at the same time, the alarm panel
may return to the "Set" status.
Key Box
This zone is mainly used in Scandinavia. If this zone is opened, this event is saved in the alarm
panel memory. It can also be transmitted via the telephone dialler at the same time. It does not trig-
ger an alarm.
If a zone of this type is required, the installer usually connects the alarm wires of this zone (usually
the auxiliary contacts of a door contact) to an external key box and the tamper wires to the tamper
switch of the housing.
If the housing is opened, the wireless alarm panel saves the event and reports it to the alarm re-
ception centre.
Tamper Acti-
vated
This zone is used for tamper monitoring of external devices. Monitoring of this zone is permanently
enabled. If the alarm panel is disarmed, only the internal siren is triggered. If the alarm panel is
armed, the external siren and strobe are triggered and communication is sent according to the con-
figuration.
Log only
If a "Log Only" zone is triggered (alarm or tampering), only a log book entry is created and an out-
put that follows this zone is triggered. The zone can be triggered when the alarm panel is armed or
disarmed.
"Log Only" zones can be assigned to multiple partitions and can have the "Chime" attribute.
Exit Terminate
This zone is used to cancel the exit delay for a partition with the "Exit Terminate" attribute. This
zone type is typically used for key switch (NO). Note: this zone is enabled during the exit time but
disabled when the wireless alarm panel is armed or disarmed. If the "Chime" attribute is assigned
to this zone, the doorbell sounds both when the wireless alarm panel is armed and disarmed.
Lock Set
This zone is used to cancel the exit delay for a partition with the "Lock Set" attribute. This zone type
is typically used for a switch (NO). Note: this zone is enabled during the exit time and when the
wireless alarm panel is armed. This zone can be assigned to the "Inverted" attribute.
Ext WD Fault
This zone is used to monitor the fault output of external sounders. If a fault output with this zone
type is triggered, "Ext WD Fault" appears on the display. This zone type is not available for wireless
zones.
HUD Fault
This zone is used to monitor the fault output of wired hold up signalling devices. If a hold up device
with this zone type is triggered, "HUD Fault" appears on the display. This message also appears on
the display if the user tries to arm the wireless alarm panel while an alarm is active. The user can
override the fault and arm the system. If this fault is triggered while the system is armed, a log book
entry is created and the communication configured accordingly is started, but no alarm is triggered
until the wireless alarm panel is disarmed. This zone type is not available for wireless zones.
Summary of Contents for SECVEST FUAA50 Series
Page 12: ...Device overview 12 International key assignment...
Page 39: ...Configuration 39 Communication...
Page 46: ...Configuration 46 Components Teach in via web interface...
Page 74: ...Configuration 74 Outputs...
Page 85: ...Configuration 85 1 Select menu item Type...
Page 94: ...Configuration 94...
Page 111: ...Configuration 111 System...
Page 148: ...Configuration 148 Communication Network...
Page 157: ...Configuration 157 ARC reporting...
Page 159: ...Configuration 159...
Page 177: ...Configuration 177 Voice dialler S W 3 00 05...
Page 185: ...Configuration 185...
Page 216: ...Configuration 216...
Page 229: ...Configuration 229 Log S W v2 01 08...
Page 278: ...Appendix 278...
Page 326: ......