Configuration
87
On the wireless or wired output, select the type "Combination output".
You have set up "Combination output 1". You can use this to enable "Wireless output 203" on the alarm panel. Assign
"Combination output 1" as the type for "Wireless output 203".
You have to select one mode for each "combination output". This mode can be ALL (AND) or ANY (OR).
For the AND mode,
all
inputs of the "combination output" have to be enabled for it to function.
For the OR mode,
any
inputs of the "combination output" may be enabled for it to function.
Example:
Requirement:
A wireless output should switch when a door (Zone 203) is open AND an installer has logged in in installer mode.
The solution:
Configure the wireless output with the type "Combination output 1" and configure
“Combination output 1” as follows:
Combination output
Mode
input
1
ALL (AND)
Input 1 type = Installer on site
Input 2 type = Zone follow (Zone 203)
Note
An input may be the output of another "combination output". However, you can only select "combination outputs" with
a number higher than the inputs.
For example, if the alarm panel supports 10 “combination outputs”, and you specify "Combination output 8", you can
only use the outputs from "Combination output 9" and "Combination output 10" as inputs.
Summary of Contents for SECVEST FUAA50 Series
Page 12: ...Device overview 12 International key assignment...
Page 39: ...Configuration 39 Communication...
Page 46: ...Configuration 46 Components Teach in via web interface...
Page 74: ...Configuration 74 Outputs...
Page 85: ...Configuration 85 1 Select menu item Type...
Page 94: ...Configuration 94...
Page 111: ...Configuration 111 System...
Page 148: ...Configuration 148 Communication Network...
Page 157: ...Configuration 157 ARC reporting...
Page 159: ...Configuration 159...
Page 177: ...Configuration 177 Voice dialler S W 3 00 05...
Page 185: ...Configuration 185...
Page 216: ...Configuration 216...
Page 229: ...Configuration 229 Log S W v2 01 08...
Page 278: ...Appendix 278...
Page 326: ......