Configuration
115
Germany
Luxembourg
Note
Every country has different settings for PSTN communication and alarm reporting or
the start and end of summer/winter time (daylight saving time).
Changing the country settings does not change the selected language.
The country defaults are used for the following:
All countries
Automatic time adjustment for summer/winter time (start and end of summer
time, country-specific)
France
FTA (First To Alarm zone lockout) operation
This locks the zone in which the alarm was first triggered in a partition so
that it cannot trigger any further alarms/faults until the zone has been re-
stored or the alarm control panel has been disarmed.
Denmark
PSTN modem ring tone detection
The PSTN modem ring tone detection algorithm must allow additional time
between the ring tones to establish whether the ringing has stopped. 6 s is
normal, but for Denmark it is 8 s.
Netherlands
The handshake tone frequencies for Fast Format and the Scan-
com/Scanfast social care protocols are different in the Netherlands.
Usually, the handshake tone frequencies for Fast Format are
1400 Hz/2300 Hz but they are 1600 Hz/2000 Hz in the Netherlands.
Default settings
The following factory defaults are currently affected by the country defaults,
see below and the "Factory defaults" appendix.
UK
"Installer Mode -> System -> Security -> Jamming" "TAMPER
PROTECTION" factory default
and
"Installer Mode -> System -> Security -> Supervision" "TAMPER
PROTECTION" factory default
to fulfil PD6662:2010
All other countries, FAULT factory default
"Installer Mode -> System -> Confirmation -> Confirmation Mode" BS8243
default setting
All other countries, BASIC factory default
Germany (S/W >= 1.01.00)
"Installer Mode -> Partitions -> Partitions 1
–4 -> All set -> Siren time ext. ->
3 minutes"
"Installer Mode -> Partitions -> Partitions 1
–4 -> Internal set -> Siren time
ext. -> 3 minutes"
All other countries and Germany (S/W < 1.01.00), 15 minutes fac-
tory default
Summary of Contents for SECVEST FUAA50 Series
Page 12: ...Device overview 12 International key assignment...
Page 39: ...Configuration 39 Communication...
Page 46: ...Configuration 46 Components Teach in via web interface...
Page 74: ...Configuration 74 Outputs...
Page 85: ...Configuration 85 1 Select menu item Type...
Page 94: ...Configuration 94...
Page 111: ...Configuration 111 System...
Page 148: ...Configuration 148 Communication Network...
Page 157: ...Configuration 157 ARC reporting...
Page 159: ...Configuration 159...
Page 177: ...Configuration 177 Voice dialler S W 3 00 05...
Page 185: ...Configuration 185...
Page 216: ...Configuration 216...
Page 229: ...Configuration 229 Log S W v2 01 08...
Page 278: ...Appendix 278...
Page 326: ......