Configuration
81
Type
Explanation
Can be assigned
to partitions
Complete arming
This output is only activated when all of the partitions con-
figured in the system are armed.
Yes
Setting Complete
This output is activated (for approx. 10 seconds) when the
system or partition is armed or internally armed.
Yes
Enabled
This output is activated when the partition is armed.
Yes
Rearmed
The output is activated in an internally armed system
when the system is rearmed at least once.
If the confirmation mode has been set to DD243 or
BS8243, the alarm panel activates the output as soon as
the system is rearmed (after the confirmation timer).
If the confirmation mode "Basic" is selected, the alarm
panel activates the output as soon as the system is re-
armed (after the siren time has expired).
In a system with partitions, the output can be assigned to
different partitions.
The output is deactivated again when a user or installer
resets the system or the partition.
Yes
Part Set Ready
This output is activated when the partition is ready to be
internally armed.
If a detector is assigned to more than one partition, the
partition in question is ready even if this detector is still
open.
Yes
Part Setting Complete
This output is activated (for approx. 10 seconds) when the
system or partition is
INTERNALLY
armed.
Yes
Part Set
This output is activated when a partition is internally
armed.
Yes
Set Fault
This output is activated when arming fails. It remains acti-
vated until the user confirms the fault.
yes
Autoset Warning
This output is activated when the warning time for auto-
matic arming is running. (See menu "Schedulers Set/Un-
set".)
This output is deactivated when the system is armed or a
user delays or cancels automatic arming.
yes
Unset Complete
The output is activated as soon as the system is disarmed
or deactivated after an alarm.
The output is activated for approx. 10 seconds.
Yes
Zone Omit (Setting)
This output is activated when the user omits a zone while
arming the system.
The output is deactivated as soon as the alarm panel re-
sets the zone.
Yes
Summary of Contents for SECVEST FUAA50 Series
Page 12: ...Device overview 12 International key assignment...
Page 39: ...Configuration 39 Communication...
Page 46: ...Configuration 46 Components Teach in via web interface...
Page 74: ...Configuration 74 Outputs...
Page 85: ...Configuration 85 1 Select menu item Type...
Page 94: ...Configuration 94...
Page 111: ...Configuration 111 System...
Page 148: ...Configuration 148 Communication Network...
Page 157: ...Configuration 157 ARC reporting...
Page 159: ...Configuration 159...
Page 177: ...Configuration 177 Voice dialler S W 3 00 05...
Page 185: ...Configuration 185...
Page 216: ...Configuration 216...
Page 229: ...Configuration 229 Log S W v2 01 08...
Page 278: ...Appendix 278...
Page 326: ......