Configuration
203
remote control.
Ethernet Line
Fault Delay
Time in seconds until the alarm system responds to a fault in the internet connec-
tion.
PSTN Line
Fault Delay
Time in seconds until the alarm system responds to a fault in the telephone connec-
tion.
GSM Line
Fault Delay
(only when wireless mobile mod-
ule is used)
IP Mobile / Mobile Line Fail
Delay
Time in seconds until the alarm system responds to a fault in the wireless mobile
connection.
GSM Omit Digit
(only when wireless mobile mod-
ule is used)
Mobile without outside dial-
ling
Enabled
If activated, the first digit of the saved telephone number in the phone book is not
selected with the rest of the number for a GSM / wireless mobile connection.
If you want to make calls from a telephone of a private branch exchange into the
public telephone network, you must first dial what is known as the exchange ac-
cess code (code for an outside line) before you dial the telephone number.
In this case, the exchange access code must be entered as the first digit in the
phone book on the alarm panel.
This is followed by the actual destination telephone number.
The exchange access code is available from the administrator of the private
branch exchange or in the instructions of the private branch exchange.
It is usually the number "0"; in the UK it is usually the number "9".
Format of the telephone number: "0 0123 4567890".
The alarm panel can therefore also be connected to an analogue extension of a
private branch exchange.
This extension does not necessarily have to be set up for automatic outside line
dialling.
Deactivated
On a private branch exchange, if you are using an extension that is programmed for
automatic outside dialling, or if you are using a regular analogue telephone connec-
tion, select "Deactivated".
The setting "GSM Omit Digit=Activated" and “Mobile Omit Digit=Activated” affects
numbers to dial for:
ARC reporting
Nursing emergency call
Voice dialler
SMS messages are normally sent only via GSM/wireless mobile. The normal desti-
nation numbers are saved in the phone book:
Format of the telephone number: "0123 4567890".
With a private branch exchange, the alarm panel is connected to an analogue ex-
tension without automatic outside line dialling.
If you want to implement SMS dispatch that starts on the analogue connection of
the alarm system, then under
Installer Mode
Communications
SMS
PSTN SMS
Service Centre Tel.
configure the exchange access code before the actual service centre telephone
number.
Format of the telephone number: "0 0123 4567890".
Summary of Contents for SECVEST FUAA50 Series
Page 12: ...Device overview 12 International key assignment...
Page 39: ...Configuration 39 Communication...
Page 46: ...Configuration 46 Components Teach in via web interface...
Page 74: ...Configuration 74 Outputs...
Page 85: ...Configuration 85 1 Select menu item Type...
Page 94: ...Configuration 94...
Page 111: ...Configuration 111 System...
Page 148: ...Configuration 148 Communication Network...
Page 157: ...Configuration 157 ARC reporting...
Page 159: ...Configuration 159...
Page 177: ...Configuration 177 Voice dialler S W 3 00 05...
Page 185: ...Configuration 185...
Page 216: ...Configuration 216...
Page 229: ...Configuration 229 Log S W v2 01 08...
Page 278: ...Appendix 278...
Page 326: ......