Configuration
138
Name/function
Explanation (checkbox)
Silence Alerts
(silent warnings)
This option controls the length of time in which warning tones (a brief "beep" every
few minutes) are sounded.
Dropdown selection field for:
User Code
Warnings are sounded until a user enters their code to confirm the warning.
30 minutes
60 minutes
120 minutes
Warnings are sounded for the set amount of time. The warning tones can be
stopped by entering a user code.
No alert tones
No acoustic alerts are sounded.
Note
The alarm panel does not display any warnings as long as a partition is still armed.
Abort time
Input field for the alarm abort time in seconds (value between 0 and 120).
The alarm panel always starts this time when an alarm has been triggered. If a user
mutes the alarm during this time, no installer reset is required.
If an alarm occurs and a user disarms the system
within
this time, "Alarm Abort"
outputs are activated and an alarm abort is reported.
Siren Delay (User)
“Siren Delay (User)” in minutes (value between 0 – 10).
0 means disarmed.
Note
When “Siren Delay (User-based)” is enabled (> 0), the entire behaviour of the siren
delay is blocked in the partition settings.
This does not comply with EN 50131.
ARC communication and Confirmation Mode affect the siren delay in the partition
settings.
Note
Siren Delay (User)
only
affects the outdoor sirens.
Note
In the event of a fire, intruder or 24h alarm, there is no siren delay (user)
Entry Alarm Delay
Additional delay when deviating from the entry route.
Select whether the user is permitted an additional time of 30 seconds when deviat-
ing from the entry route, before an external alarm is started.
Summary of Contents for SECVEST FUAA50 Series
Page 12: ...Device overview 12 International key assignment...
Page 39: ...Configuration 39 Communication...
Page 46: ...Configuration 46 Components Teach in via web interface...
Page 74: ...Configuration 74 Outputs...
Page 85: ...Configuration 85 1 Select menu item Type...
Page 94: ...Configuration 94...
Page 111: ...Configuration 111 System...
Page 148: ...Configuration 148 Communication Network...
Page 157: ...Configuration 157 ARC reporting...
Page 159: ...Configuration 159...
Page 177: ...Configuration 177 Voice dialler S W 3 00 05...
Page 185: ...Configuration 185...
Page 216: ...Configuration 216...
Page 229: ...Configuration 229 Log S W v2 01 08...
Page 278: ...Appendix 278...
Page 326: ......