Configuration
124
Name/function
Explanation (checkbox)
Quick Set
Enabled
Alarm system can be armed using the symbol keys without entering the user code
first.
Deactivated
Alarm system can only be armed after the user code has been entered.
Quick Omit
Enabled
Open zones are automatically omitted when the alarm system is armed (if the zone
attributes for omission allow).
Deactivated
Open zones must be manually omitted when the alarm system is armed.
User Code Req’d
Use this option to ensure that an installer only has access to the system when a
user is present.
Activated / J (factory default)
After the installer has entered their code, the system prompts the user to enter their
user code. Only once a user code has also been entered does the installer gain ac-
cess to the system.
Alarm panel
Installer Mode -> System -> User Access -> User Code Required
J (factory default)
Deactivated
The installer can access installer mode after entering their code; no additional user
code is required.
Note
The "Disarmed/No" setting is
not
compliant with EN50131.
The factory default is required to be compliant, i.e. Level 2 users must be
awarded Level 3 user access (Installer).
EN50131-1, chapter 8.3.1 access levels (with reference to EN50131-3,
chapter 8.3.1 access levels (AL))
"Access to access level 3 must be prevented unless either
a) ->access was enabled by a user with access level 2 or
b) -
> …."
The "Disarmed/No" setting
only
complies with BS8243 when the user has provided
written consent.
2 Way Replies
Enabled
There is active status feedback from the wireless alarm system to the wireless re-
mote control, wireless control device, Secvest key and additional door lock.
Deactivated
2 Way Replies are deactivated.
Summary of Contents for SECVEST FUAA50 Series
Page 12: ...Device overview 12 International key assignment...
Page 39: ...Configuration 39 Communication...
Page 46: ...Configuration 46 Components Teach in via web interface...
Page 74: ...Configuration 74 Outputs...
Page 85: ...Configuration 85 1 Select menu item Type...
Page 94: ...Configuration 94...
Page 111: ...Configuration 111 System...
Page 148: ...Configuration 148 Communication Network...
Page 157: ...Configuration 157 ARC reporting...
Page 159: ...Configuration 159...
Page 177: ...Configuration 177 Voice dialler S W 3 00 05...
Page 185: ...Configuration 185...
Page 216: ...Configuration 216...
Page 229: ...Configuration 229 Log S W v2 01 08...
Page 278: ...Appendix 278...
Page 326: ......