Configuration
98
Configure partitions
Part Set
Name/function
Explanation
Name
Unique name of the partition.
The partition can be assigned an individual name here, e.g. apartment, workshop,
office. Max. 12 characters are allowed.
The alarm panel displays this name during arming.
Part set
Settings for the internal arming of the partition
Exit Mode
Select the mode of internal arming when exiting the premises.
Note:
See also user guide Chapter "8. Arming and disarming the system"
Timed Set
Use this option to internally arm the partition only after a set delay time. Under
"Exit time" select the corresponding time. The alarm panel logs the start of this
timed internal arming.
This option does not comply with BS8243:2010.