Configuration
52
1. Select menu item
Type
Type
Explanation
Not
used
A zone that is not used because no wireless detector is taught in (no "radio detector learned") or
because its input is not wired to a detector should be configured as zone type "Not Used". The
alarm system does not respond when an event triggers a detector in this zone.
Normal Alarm
If the wireless alarm panel is armed, this zone immediately triggers an alarm if a wireless detector
sends a change to the alarm panel or the status of the alarm zone changes (e.g. alarm contact
opens).
Note
Zone type "Normal Alarm" with additional functionality of pry-attempt monitoring for ABUS mecha-
tronics products such as the FOS 550 E window bar lock, additional door lock or FOS 400 E win-
dow lock. If using a mechatronics product intended for Secvest, configure zone type "Normal
Alarm" in the alarm panel. When the alarm panel is disarmed, these detectors are monitored both
for pry attempts and opening. For this, the window must be closed and the lock secured. Monitoring
begins 30 seconds after locking, as a self-calibration time of 30 seconds is required. If the mecha-
tronic additional lock is unlocked, monitoring stops. If an attempt is made to open the window with-
out first unlocking the additional lock, an alarm may be triggered by the movement of the window
leaf. Pry-attempt monitoring can be disabled in the attributes (see "Zone attributes" below).
A passive glass breakage detector can also be connected to some mechatronic products. This de-
tector sends an alarm when it detects glass breakage, which always leads to an alarm response on
the alarm panel. The alarm panel carries out actions intended for an armed or disarmed status.
Zone Lock
The zone must be locked (closed) in order to arm or internally arm the wireless alarm panel. If the
wireless alarm panel is armed or internally armed, opening this zone does not trigger an alarm.
This zone is used with lock switch contacts.
Note
This zone type was used in the Secvest 2WAY as a zone attribute rather than a zone type.
Exit Norm Alm
A zone configured as "Exit Norm Alm" behaves similarly to a "Normal Alarm" zone. A zone of this
type, however, starts an alarm even when the detector is triggered during the exit time.
Panic alarm
This zone always triggers an alarm, regardless of whether the alarm panel is armed or disarmed. A
hold up alarm can also be transmitted silently (communications). The configuration menu can only
be exited when this zone is closed. Teach in the hold up button (wireless or wall) in this zone.
Fire
This zone always triggers an alarm, regardless of whether the alarm panel is armed or disarmed.
The alarm is triggered via the sounder in the wireless alarm panel and on the outdoor siren (exter-
nal siren) as a pulsed fire alarm sound. Teach in only smoke alarm devices in this zone.
24 Hour Alarm
This zone always triggers an immediate alarm. When the alarm panel is disarmed, the alarm is first
triggered via the integrated sounder in the alarm panel. When the alarm panel is armed, the siren
output is also activated. If a 24 hour zone is disabled, it is only disabled when the alarm panel is
disarmed.
Perimeter Warn-
ing
This zone triggers a pre-alarm when the alarm system is armed or internally armed. The alarm
panel beeps twice every five seconds. "Perimeter Warning" appears on the display every five sec-
onds. Teach in outdoor motion detectors in this zone, for example.
The wireless outdoor sirens flash and sound for approx. 1 s every five seconds.
The info module beeps every 1 s and the red alarm LED lights up.
The indoor siren sounds every 1 s. This siren must be supplied by a power supply unit for this pur-
pose, however, and the "alarm only" jumper must not be connected.
(This tone is an "info" tone rather than an "alarm" tone.)
All signals are active for a duration of 30 s.
A "Perimeter Warning" output is activated for 30 s.
When the system is disarmed only the doorbell ("chime") sounds, if configured.
Final Door
When the alarm panel is armed, this zone triggers an alarm once the set delay time (entry delay)
has expired. Use this zone type for the magnetic contact on the entrance door, for example. When
Summary of Contents for SECVEST FUAA50 Series
Page 12: ...Device overview 12 International key assignment...
Page 39: ...Configuration 39 Communication...
Page 46: ...Configuration 46 Components Teach in via web interface...
Page 74: ...Configuration 74 Outputs...
Page 85: ...Configuration 85 1 Select menu item Type...
Page 94: ...Configuration 94...
Page 111: ...Configuration 111 System...
Page 148: ...Configuration 148 Communication Network...
Page 157: ...Configuration 157 ARC reporting...
Page 159: ...Configuration 159...
Page 177: ...Configuration 177 Voice dialler S W 3 00 05...
Page 185: ...Configuration 185...
Page 216: ...Configuration 216...
Page 229: ...Configuration 229 Log S W v2 01 08...
Page 278: ...Appendix 278...
Page 326: ......