Configuration
217
Function
Meaning
Wireless control
panel
Testing of wireless control panels is carried out in the web interface in the same manner as
on the alarm panel.
Press the function buttons on the wireless control device one after the other.
Wait 2 to 3 seconds between each button so that the control device can send each message.
A corresponding letter appears on the display in response:
A = "arm" button (closed lock)
C = "internal arm" button (*)
D= "query status" button (?)
B = "disarm" button (open lock)
On the
Web
you will also see:
Arm system key
Arm system internally key
Status query
Disarm system key
To test the number buttons, press 4 or 6 numerical buttons (corresponding to the set code
length) and then a function button: Example:
Press
: 1234?
Displayed
: 1234D (status query)
Press the dual keys (fire alarm, hold up alarm, medical emergency or social care alarm) at
the same time to test them. On the display:
F = dual keys fire alarm
P = dual keys hold up
M = dual keys medical emergency
H = dual keys social care alarm
On the
Web
you will also see:
Fire key
Intrusion key
Medical emergency call key
Social Care Key
The lower "*" and "#" button on the control device cannot be tested.
Summary of Contents for SECVEST FUAA50 Series
Page 12: ...Device overview 12 International key assignment...
Page 39: ...Configuration 39 Communication...
Page 46: ...Configuration 46 Components Teach in via web interface...
Page 74: ...Configuration 74 Outputs...
Page 85: ...Configuration 85 1 Select menu item Type...
Page 94: ...Configuration 94...
Page 111: ...Configuration 111 System...
Page 148: ...Configuration 148 Communication Network...
Page 157: ...Configuration 157 ARC reporting...
Page 159: ...Configuration 159...
Page 177: ...Configuration 177 Voice dialler S W 3 00 05...
Page 185: ...Configuration 185...
Page 216: ...Configuration 216...
Page 229: ...Configuration 229 Log S W v2 01 08...
Page 278: ...Appendix 278...
Page 326: ......