Configuration
221
Function
Meaning
Emergency buttons
Testing of the remote control is carried out in the web interface in the same manner as on the
alarm panel.
Press the button on a pendant.
The following information appears on the display
which user is assigned to this emergency button
the function of this pendant
HUA = hold up alarm
Medical = medical emergency
PFN alarm = social care alarm
the received signal strength (RSSI)
Example
User: User 002
Func: Medical
RSSI: 9
ARC reporting
Testing of the ARC reporting function is carried out in the web interface in the same manner
as on the alarm panel.
ARC Reporting must be activated and the contact must be saved in the phone book.
Installer Mode->Communications->ARC Reporting ->Call Mode ->Single
(or Alternate)
A list of the available connected transmission paths can be seen:
Ethernet, Ethernet / IP Mobile
When this is selected, the 2 possible configured recipients (IP Recipient 1, IP Recipient 2)
are displayed with their contact names as stored in the phone book.
Scroll to the desired contact. Press the "Select” or “Start” key in the web interface.
The alarm panel sends a test call to this recipient.
The event (or trigger) "Test" is sent according to the set protocol.
PSTN
When this is selected, the 2 possible configured recipients (Tel Recipient 1, Tel Recipient
2) are displayed with their contact names as stored in the phone book.
Scroll to the desired contact. Press the "Select” or “Start” key in the web interface.
The alarm panel sends a test call to this recipient.
The event (or trigger) "Test" is sent according to the set protocol.
GSM / Mobile
When this is selected, the 2 possible configured recipients (Tel Recipient 1, Tel Recipient
2) are displayed with their contact names as stored in the phone book.
Scroll to the desired contact. Press the "Select” or “Start” key in the web interface.
The alarm panel sends a test call to this recipient.
The event (or trigger) "Test" is sent according to the set protocol.
During the test call a series of progress messages appear on the display.
If the test call was not successful, the display shows a brief message with the
cause of the error.
Summary of Contents for SECVEST FUAA50 Series
Page 12: ...Device overview 12 International key assignment...
Page 39: ...Configuration 39 Communication...
Page 46: ...Configuration 46 Components Teach in via web interface...
Page 74: ...Configuration 74 Outputs...
Page 85: ...Configuration 85 1 Select menu item Type...
Page 94: ...Configuration 94...
Page 111: ...Configuration 111 System...
Page 148: ...Configuration 148 Communication Network...
Page 157: ...Configuration 157 ARC reporting...
Page 159: ...Configuration 159...
Page 177: ...Configuration 177 Voice dialler S W 3 00 05...
Page 185: ...Configuration 185...
Page 216: ...Configuration 216...
Page 229: ...Configuration 229 Log S W v2 01 08...
Page 278: ...Appendix 278...
Page 326: ......