Appendix
306
"HUA Confirm sound generator #"
Hold up alarm confirmed by sound generator #
"HUA Confirm Sound Generator"
Hold up alarm confirmed by sound generator
"HUA Cnf RF HD U---"
Hold up alarm confirmed via user's emergency call transmitter ==
"HUA Confirm Pa CDV=="
Hold up alarm confirmed via HUA keys on wireless control panel.
"HUA Confirm SRN=="
Hold up alarm confirmed via external siren --
"HUA Cnf RF MD U---"
Hold up alarm confirmed via user's dead man switch ==
"HUA Confirm WAM=="
Hold up alarm confirmed via WUM
"HUA Confirm Websvr"
Hold up alarm confirmed by web server
"HUA Confirm Z==="
Hold up alarm confirmed from zone ==
"HUA Conf Panel Lid"
Hold up alarm confirmed by tamper contact with the alarm control panel
"Hold Up Alarm"
Hold up alarm triggered on control panel
"HUD Fault Z ==="
Fault with hold up zone ===
"Override"
System has been activated despite warning
"HUA U-- -- Alarm"
Alarm triggered by remote control of user --
"HUA U-- Low Batt"
User's remote control device -- has a low battery
"Invalid"
Invalid
"WAM== Superv Fail"
WAM == Wireless monitoring failed
"WAM== Battery Rstr"
WAM== Battery Rstr
"WAM== Low Battery"
WAM== Low Battery
"WAM== PSU Restore"
WAM== Fault with power supply
"WAM== PSU Fail"
WAM == Power supply restore
"WAM== RF OK"
WAM == wireless monitoring restore
"WAM== RF Warning"
WAM == no wireless connection with the alarm panel for over 15 min
"WAM== Tamper Rstr"
WAM== Tampering restore
"WAM== Tamper"
WAM== Tampering
"WAM== Sndr Tamper"
WAM== Sounder tampering
"WAM== Sndr Trouble"
WAM== Sounder fault
"WAM== Sndr Tmp Rst"
WAM== Sounder tampering restore
"WAM== Sndr Trb Rst"
WAM== Sounder trouble reset
"WAM== Superv Rstr"
WAM == Wireless monitoring restore
"WAM== Superv Rstr"
WAM == Wireless monitoring restore
"WAM== SupervFail"
WAM== Wireless monitoring failed
"Flood Z== Alarm"
Flood detector zone == Alarm"
"Flood Z== Restore"
Flood detector zone == was reset
"Websvr Excess Keys"
Tampering via too many incorrect code entries on the webserver access
"Websvr Ex Keys Rst"
Tampering via too many incorrect code entries on the webserver access,
has been reset
"Defaults Loaded"
System set to default settings
"WSN== Trouble Rstr"
Fault with wired sirens has been reset
"WSN== Trouble"
Wired sounder fault
"Z== Follow Photos"
Photos were recorded because zone === was triggered.
"Z== PSU Rst"
Zone == smoke detector power supply unit fault reset
"Z== PSU Flt"
Zone == smoke detector power supply unit fault
"Z== Smoke PSU Rst"
Zone === smoke detector power supply unit fault reset
Summary of Contents for SECVEST FUAA50 Series
Page 12: ...Device overview 12 International key assignment...
Page 39: ...Configuration 39 Communication...
Page 46: ...Configuration 46 Components Teach in via web interface...
Page 74: ...Configuration 74 Outputs...
Page 85: ...Configuration 85 1 Select menu item Type...
Page 94: ...Configuration 94...
Page 111: ...Configuration 111 System...
Page 148: ...Configuration 148 Communication Network...
Page 157: ...Configuration 157 ARC reporting...
Page 159: ...Configuration 159...
Page 177: ...Configuration 177 Voice dialler S W 3 00 05...
Page 185: ...Configuration 185...
Page 216: ...Configuration 216...
Page 229: ...Configuration 229 Log S W v2 01 08...
Page 278: ...Appendix 278...
Page 326: ......