Appendix
239
Connections
L
N
Mains connection
110 V/230 V AC, 50/60 Hz, (85-265 V AC, 50/60 Hz)
L
– line, single phase (black or brown)
– protective earth (yellow/green)
N
– neutral (blue)
- DC IN +
13.8 V
External PSU input
13.8 V DC, external PSU at least 1.7 A
See Power supply section for more details
0 V 12 V
AUX
Voltage output
13.8 V DC
up to 700 mA, main pcba issue < 7
up to 600 mA, main pcba issue >= 7
Maximum output residual ripple (ripple voltage):
0.2 Vp-p
Aux output fault triggered at 11.5 V, ok from 12.0 V
See Power supply section for more details
Note
This output is
not
buffered by the battery in case of power failure.
The output voltage during a power failure is directly 0 V.
+BATT1 ,+BATT2
Battery polymer lithium ion, 7.4 V, 2500 mAh
OP 301, OP 302
Relay output
Potential-free changeover contact NO/C/NC
Max. contact capacity: 500 mA @ 24 V AC rms or 30 V DC
OP 303, OP 304
Transistor output
Open-drain
Max. contact capacity: 500 mA @ 13.8 V DC
Note
These outputs will drop to 0 V during power failures
TR
A negative tamper input
The input is switched to the inactive low state (ground potential) by
the connected siren. The threshold voltages are > 4 V for active
and < 3.6 V for inactive.
TRB
A negative fault input
The input is switched to the inactive low state (ground potential) by
the connected siren. The threshold voltages are > 4 V for active
and < 3.6 V for inactive.
10/100 LAN
Ethernet/LAN
Cat5e patch cable, RJ45 male
Connector at each end, suitable for 10/100Base-T
USB TYPE-B
USB Mini-B connector for alarm panel
USB-A connector for PC
Max. length 3 m
A B
Interface for analogue telephone connection to the public tele-
phone network, a private branch exchange or an integrated ac-
cess device (IAD [router] e.g. Vodafone Easybox xyz or
FRITZ!Box vwxy)
Approved for telecommunications in accordance with TBR-
21/CTR21 (ETSI ES203021)
> 18 V
Summary of Contents for SECVEST FUAA50 Series
Page 12: ...Device overview 12 International key assignment...
Page 39: ...Configuration 39 Communication...
Page 46: ...Configuration 46 Components Teach in via web interface...
Page 74: ...Configuration 74 Outputs...
Page 85: ...Configuration 85 1 Select menu item Type...
Page 94: ...Configuration 94...
Page 111: ...Configuration 111 System...
Page 148: ...Configuration 148 Communication Network...
Page 157: ...Configuration 157 ARC reporting...
Page 159: ...Configuration 159...
Page 177: ...Configuration 177 Voice dialler S W 3 00 05...
Page 185: ...Configuration 185...
Page 216: ...Configuration 216...
Page 229: ...Configuration 229 Log S W v2 01 08...
Page 278: ...Appendix 278...
Page 326: ......