Safety information
10
The operator is liable for any costs incurred for in-
volving rescue services such as the fire brigade or
police.
For this reason, read these instructions carefully
and ensure that lines and components used are
labelled precisely when the system is installed.
Wireless operation
Note
No wireless licence is required for Secvest and its
components.
The send/receive properties could be affected by
other signals (e.g. DECT telephones).
The wireless devices in this system have been
tested by an independently accredited laboratory
for RED Directive 2014/53/EU or for R&TTE certi-
fication.
Mounting location of the alarm panel
Note
The alarm panel should be positioned in a safe
place out of sight of possible intruders and easily
accessible to the operator.
The alarm panel should be mounted on a flat sur-
face in order to ensure that the back of the device
cannot be tampered with when the alarm panel is
mounted.
The alarm panel should be mounted at a conven-
ient height (between 1.5 and 2 m).
Note
If small children are present, the alarm panel
should be mounted out of their reach.
Note
Position the alarm panel so that signal tones can
be heard even outside of the area being moni-
tored.
The alarm panel should be positioned within a
monitored zone so that an unauthorised person
would have to enter a monitored area first before
gaining access to the panel when it is armed.
The alarm panel should be mounted near a socket
or power supply.
If the telephone dialler is used, the alarm panel
must be connected to a telephone connection.
The alarm panel should be mounted at least 1 me-
tre away from metal objects (e.g. mirrors or radia-
tors).
Processing priority
Note
If several detectors are activated at the same time,
the alarm control panel always processes panic
zones (panic transmitters) and normal alarms (bur-
glar alarms) first, followed by fire zones (smoke
alarm devices) and then followed by all other zone
types (alarm types)
The alarm control panel always processesalarms
ahead of warnings (fault messages).
Summary of Contents for SECVEST FUAA50 Series
Page 12: ...Device overview 12 International key assignment...
Page 39: ...Configuration 39 Communication...
Page 46: ...Configuration 46 Components Teach in via web interface...
Page 74: ...Configuration 74 Outputs...
Page 85: ...Configuration 85 1 Select menu item Type...
Page 94: ...Configuration 94...
Page 111: ...Configuration 111 System...
Page 148: ...Configuration 148 Communication Network...
Page 157: ...Configuration 157 ARC reporting...
Page 159: ...Configuration 159...
Page 177: ...Configuration 177 Voice dialler S W 3 00 05...
Page 185: ...Configuration 185...
Page 216: ...Configuration 216...
Page 229: ...Configuration 229 Log S W v2 01 08...
Page 278: ...Appendix 278...
Page 326: ......