Configuration
137
Name/function
Explanation (checkbox)
Ctrl Device Unset Full Set
Select whether
armed
partitions can only be disarmed using the
wireless control
device
when the delay time has been started beforehand ("Final Door" zone is trig-
gered).
Dropdown selection field for:
Always
The user can always disarm the possible partitions without the entry time being
started first.
During entry time
The user must first open a "Final Door" zone. This starts the entry delay. The
user can now disarm the possible partitions.
Partitions for which no entry delay has started remain armed.
Ctrl Device Unset Part Set
Select whether
internally armed
partitions can only be disarmed using the
wire-
less control device
when the delay time has been started beforehand ("Final
Door" zone is triggered).
Dropdown selection field for:
Always
The user can always disarm the possible partitions without the entry time being
started first.
During entry time
The user must first open a "Final Door" zone. This starts the entry delay. The
user can now disarm the possible partitions.
Partitions for which no entry delay has started remain armed.
Auto Rearm
Appears when the following is set:
System->Confirmation->Confirmation Mode->Basic
Select how often the system automatically rearms after the siren time has expired.
Dropdown selection field for:
Never
The alarm panel never rearms. The alarm panel switches to the alarm status
just one time.
1 x, 2 x, 3 x, 4 x, 5 x
Always
T
he system rearms all closed zones but not the detectors still sending alarm
signals.
One of these settings is required in order to comply with EN 50131.
If the system is rearmed, an acoustic internal alarm instead of the normal entry
tone is generated by the wireless alarm panel if a user enters through the entry
route.
Summary of Contents for SECVEST FUAA50 Series
Page 12: ...Device overview 12 International key assignment...
Page 39: ...Configuration 39 Communication...
Page 46: ...Configuration 46 Components Teach in via web interface...
Page 74: ...Configuration 74 Outputs...
Page 85: ...Configuration 85 1 Select menu item Type...
Page 94: ...Configuration 94...
Page 111: ...Configuration 111 System...
Page 148: ...Configuration 148 Communication Network...
Page 157: ...Configuration 157 ARC reporting...
Page 159: ...Configuration 159...
Page 177: ...Configuration 177 Voice dialler S W 3 00 05...
Page 185: ...Configuration 185...
Page 216: ...Configuration 216...
Page 229: ...Configuration 229 Log S W v2 01 08...
Page 278: ...Appendix 278...
Page 326: ......